MCA201 HAGER MCB 6000A 10kA 2P curve C 1A 2 modules
Hager
The miniature circuit breaker ensures reliable protection with a breaking capacity (Icn) of 6000 A according to CEI EN 60898-1 and (Icu) 10 kA according to CEI EN 60947-2. It operates at 230 V (Un) at 50-60 Hz and is ideal for residential and tertiary installations, protecting against overloads and short circuits. Equipped with 2 protected poles, C curve and rated current (In) of 1 A, it occupies 2 DIN modules. The miniature circuit breaker ensures reliable protection with a breaking capacity (Icn) of 6000 A according to CEI EN 60898-1 and (Icu) 10 kA according to CEI EN 60947-2. It operates at 230 V (Un) at 50-60 Hz and is ideal for residential and tertiary installations, protecting against overloads and short circuits. Equipped with 2 protected poles, C curve and rated current (In) of 1 A, it occupies 2 DIN modules.
MPNs MCA201, HAGMCA201
EAN 3250614346576
HS Code 85362010
Country of origin Poland
Weight
0.23 kg
Volumetric weight 61.33 kg
The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Product information
Technical specifications
- Degree of protection (IP)
- IP20
- Ambient temperature during operating
- -25;70 °C
- Voltage type
- AC
- Rated voltage
- 400 V
- Connectable conductor cross section solid-core
- 1;35 mm²
- Connectable conductor cross section multi-wired
- 1;25 mm²
- Rated current
- 1 A
- Width in number of modular spacings
- 2
- Power loss
- 2.11 W
- Built-in depth
- 70 mm
- Frequency
- 50;60 Hz
- Flush-mounted installation
- TRUE
- Rated insulation voltage Ui
- 500 V
- Pollution degree
- 2
- Additional equipment possible
- TRUE
- Rated impulse withstand voltage Uimp
- 6 kV
- Release characteristic
- C
- Over voltage category
- 3
- Number of protected poles
- 2
- Number of poles (total)
- 2
- Current limiting class
- 3
- Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
- 6 kA
- Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
- 10 kA
- Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
- 20 kA
- Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
- 10 kA