P1MS1P125 - Lovato - Accessory for miniature circuit breaker
Lovato
modular switch disconnector, 1 pole, rated current 125 A. modular switch disconnector, 1 pole, rated current 125 A.
MPNs P1MS1P125, LOVP1MS1P125
EAN 8013975267271
HS Code 85369095
Weight
0.08 kg
The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy
Secure payments
& many more
We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods
12 Months warranty
This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty
Returns available within 30 days
Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.
Product information
Description
<h3>Enclosed switch disconnector for isolation</h3><p>This switching component is used for load isolation, line changeover or mechanical completion of switch-disconnector assemblies in industrial panels and local machine controls. It supports safe, clearly identifiable manual operation where the operator must separate, select or transfer a power circuit from a defined handle position.</p><h4>Isolation data and handle function</h4><p>component type switch disconnector; rated current 125 A. Selection must follow rated current, pole configuration, enclosure rating and the required operating sequence. Handles, shafts, additional poles and coupling systems must be matched to the switch body so that the door command, contact position and isolation state remain mechanically consistent.</p><h4>Commissioning and maintenance</h4><p>During commissioning, check the handle position, contact sequence and enclosure closure before energizing the downstream circuit. In maintenance, compare the installed part with the wiring diagram and the mechanical assembly, then repeat the isolation and continuity checks before returning the equipment to service.</p><p>Clear marking of handle positions and pole assignment reduces errors in panels with several isolators. It also helps technicians distinguish a complete enclosed device from an accessory such as a handle, coupling system, shaft extension or additional pole.</p><p>For accessory replacement, keep the same operating role in the assembly and check the handle travel against the contact state before closing the door. For enclosed devices, verify enclosure rating, handle colour and pole count against the machine isolation requirement.</p><p>The acceptance test should include manual operation from each marked position, continuity check on the used poles and visual inspection of the coupling between handle, shaft and switch body. This keeps power isolation and local operation understandable for future interventions.</p>
<h3>Enclosed switch disconnector for isolation</h3><p>This switching component is used for load isolation, line changeover or mechanical completion of switch-disconnector assemblies in industrial panels and local machine controls. It supports safe, clearly identifiable manual operation where the operator must separate, select or transfer a power circuit from a defined handle position.</p><h4>Isolation data and handle function</h4><p>component type switch disconnector; rated current 125 A. Selection must follow rated current, pole configuration, enclosure rating and the required operating sequence. Handles, shafts, additional poles and coupling systems must be matched to the switch body so that the door command, contact position and isolation state remain mechanically consistent.</p><h4>Commissioning and maintenance</h4><p>During commissioning, check the handle position, contact sequence and enclosure closure before energizing the downstream circuit. In maintenance, compare the installed part with the wiring diagram and the mechanical assembly, then repeat the isolation and continuity checks before returning the equipment to service.</p><p>Clear marking of handle positions and pole assignment reduces errors in panels with several isolators. It also helps technicians distinguish a complete enclosed device from an accessory such as a handle, coupling system, shaft extension or additional pole.</p><p>For accessory replacement, keep the same operating role in the assembly and check the handle travel against the contact state before closing the door. For enclosed devices, verify enclosure rating, handle colour and pole count against the machine isolation requirement.</p><p>The acceptance test should include manual operation from each marked position, continuity check on the used poles and visual inspection of the coupling between handle, shaft and switch body. This keeps power isolation and local operation understandable for future interventions.</p>
Technical specifications
- Degree of protection (IP)
- IP20
- Ambient temperature during operating
- -25;70 °C
- Voltage type
- AC
- Rated voltage
- 240 V
- Connectable conductor cross section solid-core
- 1;50 mm²
- Rated current
- 125 A
- Width in number of modular spacings
- 1
- Built-in depth
- 66 mm
- Frequency
- 50;60 Hz
- Rated insulation voltage Ui
- 1000 V
- Pollution degree
- 3
- Additional equipment possible
- TRUE
- Rated impulse withstand voltage Uimp
- 4 kV
- Over voltage category
- 3
- Number of protected poles
- 1
- Concurrently switching neutral conductor
- TRUE
- Number of poles (total)
- 1