Inductive sensor NCB20-L2-N0-V1 NCB20-L2-N0-V1 Sensor head bidirectional and rotatable 20 mm flush Quick mounting bracket Usable up to SIL 2 acc. to IEC 61508 NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers Inductive sensor NCB20-L2-N0-V1 NCB20-L2-N0-V1 Sensor head bidirectional and rotatable 20 mm flush Quick mounting bracket Usable up to SIL 2 acc. to IEC 61508 NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers

MPNs 70133147, PEP70133147, NCB20-L2-N0-V1
HS Code 85365090
Weight 0.13 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Available on request

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product available in multiple conditions

Currently out of stock

Alternative condition

USD102.54

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of PEPPERL+FUCHS
To United States starting from USD27.36 by DHL Express Worldwide
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Product information

Description

Datasheet excerpt: Technical data of  NCB20-L2-N0-V1 General specifications Switching functionNormally closed (NC) Output typeNAMUR Rated operating distance20 mm Installationflush Assured operating distance0 ... 16.2 mm Actual operating distance18 ... 22 mm Reduction factor rAl 0.33 Reduction factor rCu 0.31 Reduction factor r304 0.74 Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 300 Hz Hysteresistyp. 5 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Current consumption Measuring plate not detected≥ 2.2 mA Measuring plate detected≤ 1 mA Switching state indicatorLED, yellow Functional safety related parameters Safety Integrity Level (SIL)SIL 2 MTTFd1660 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0021X Equipment protection level GbIECEx PTB 11.0021X Equipment protection level DaIECEx PTB 11.0021X Equipment protection level Dc (tc)IECEx TUR 21.0020X Equipment protection level MbIECEx PTB 11.0021X ATEX approval Equipment protection level GaPTB 00 ATEX 2032 X Equipment protection level GbPTB 00 ATEX 2032 X Equipment protection level DaPTB 00 ATEX 2032 X Equipment protection level Dc (tc)TÜV 20 ATEX 8526 X EAC conformityTR CU 012/2011 Protection classII Rated insulation voltage253 V Rated impulse withstand voltage4000 V UL approval Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0451 CCC approval Hazardous Location2020322315002302 NEPSI approval NEPSI certificateGYJ16.1394X ANZEx19.3001X Marine approvalDNVGL TAA00001A5 Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection typeConnector plug Housing materialPA Sensing facePA Degree of protectionIP66 / IP69K Connector ThreadingM12 x 1 Number of pins4 Mass130 g General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  NCB20-L2-N0-V1 General specifications Switching functionNormally closed (NC) Output typeNAMUR Rated operating distance20 mm Installationflush Assured operating distance0 ... 16.2 mm Actual operating distance18 ... 22 mm Reduction factor rAl 0.33 Reduction factor rCu 0.31 Reduction factor r304 0.74 Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 300 Hz Hysteresistyp. 5 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Current consumption Measuring plate not detected≥ 2.2 mA Measuring plate detected≤ 1 mA Switching state indicatorLED, yellow Functional safety related parameters Safety Integrity Level (SIL)SIL 2 MTTFd1660 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0021X Equipment protection level GbIECEx PTB 11.0021X Equipment protection level DaIECEx PTB 11.0021X Equipment protection level Dc (tc)IECEx TUR 21.0020X Equipment protection level MbIECEx PTB 11.0021X ATEX approval Equipment protection level GaPTB 00 ATEX 2032 X Equipment protection level GbPTB 00 ATEX 2032 X Equipment protection level DaPTB 00 ATEX 2032 X Equipment protection level Dc (tc)TÜV 20 ATEX 8526 X EAC conformityTR CU 012/2011 Protection classII Rated insulation voltage253 V Rated impulse withstand voltage4000 V UL approval Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0451 CCC approval Hazardous Location2020322315002302 NEPSI approval NEPSI certificateGYJ16.1394X ANZEx19.3001X Marine approvalDNVGL TAA00001A5 Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection typeConnector plug Housing materialPA Sensing facePA Degree of protectionIP66 / IP69K Connector ThreadingM12 x 1 Number of pins4 Mass130 g General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550