Inductive sensor NCB2-12GM40-E2-3G-3D NCB2-12GM40-E2-3G-3D 2 mm flush ATEX-/IECEx-approvals for zone 2/22 (Ex ec/tc) Inductive sensor NCB2-12GM40-E2-3G-3D NCB2-12GM40-E2-3G-3D 2 mm flush ATEX-/IECEx-approvals for zone 2/22 (Ex ec/tc)

MPNs 70126070, PEP70126070, NCB2-12GM40-E2-3G-3D
HS Code 85365090
Weight N/A

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

USD178.53

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of PEPPERL+FUCHS
Free express shipping to United States
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

Datasheet excerpt: Technical data of  NCB2-12GM40-E2-3G-3D General specifications Switching functionNormally open (NO) Output typePNP Rated operating distance2 mm Installationflush Output polarityDC Assured operating distance0 ... 1.62 mm Actual operating distance1.8 ... 2.2 mm typ. 2 mm Reduction factor rAl 0.3 Reduction factor rCu 0.17 Reduction factor r304 0.67 Reduction factor rBrass 0.35 Output type3-wire Nominal ratings Operating voltage10 ... 30 V DC Switching frequency0 ... 2500 Hz Hysteresis3 ... 15 typ. 6 % Reverse polarity protectionreverse polarity protected Short-circuit protectionpulsing Voltage drop≤ 3 V Voltage drop at IL Voltage drop IL = 200 mA, switching element on1 ... 2 V typ. 1.5 V Operating current≤ 200 mA Off-state current0 ... 0.5 mA typ. 0.01 mA No-load supply current≤ 15 mA Time delay before availability≤ 100 ms Switching state indicatorLED, yellow Functional safety related parameters MTTFd1507 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level Gc (ec)IECEx TUR 21.0017X Equipment protection level Dc (tc)IECEx TUR 21.0018X ATEX approval Equipment protection level Gc (ec)TÜV 20 ATEX 8523 X Equipment protection level Dc (tc)TÜV 20 ATEX 8524 X UL approvalcULus Listed, General Purpose, Class 2 Power Source Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Connection typecable PVC , 2 m Core cross section0.34 mm2 Housing materialStainless steel 1.4305 / AISI 303 Sensing facePBT Degree of protectionIP66 / IP67 Cable Cable diameter4.6 mm ± 0.2 mm Bending radius> 10 x cable diameter General information Scope of delivery2 self locking nuts in scope of delivery Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  NCB2-12GM40-E2-3G-3D General specifications Switching functionNormally open (NO) Output typePNP Rated operating distance2 mm Installationflush Output polarityDC Assured operating distance0 ... 1.62 mm Actual operating distance1.8 ... 2.2 mm typ. 2 mm Reduction factor rAl 0.3 Reduction factor rCu 0.17 Reduction factor r304 0.67 Reduction factor rBrass 0.35 Output type3-wire Nominal ratings Operating voltage10 ... 30 V DC Switching frequency0 ... 2500 Hz Hysteresis3 ... 15 typ. 6 % Reverse polarity protectionreverse polarity protected Short-circuit protectionpulsing Voltage drop≤ 3 V Voltage drop at IL Voltage drop IL = 200 mA, switching element on1 ... 2 V typ. 1.5 V Operating current≤ 200 mA Off-state current0 ... 0.5 mA typ. 0.01 mA No-load supply current≤ 15 mA Time delay before availability≤ 100 ms Switching state indicatorLED, yellow Functional safety related parameters MTTFd1507 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level Gc (ec)IECEx TUR 21.0017X Equipment protection level Dc (tc)IECEx TUR 21.0018X ATEX approval Equipment protection level Gc (ec)TÜV 20 ATEX 8523 X Equipment protection level Dc (tc)TÜV 20 ATEX 8524 X UL approvalcULus Listed, General Purpose, Class 2 Power Source Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Connection typecable PVC , 2 m Core cross section0.34 mm2 Housing materialStainless steel 1.4305 / AISI 303 Sensing facePBT Degree of protectionIP66 / IP67 Cable Cable diameter4.6 mm ± 0.2 mm Bending radius> 10 x cable diameter General information Scope of delivery2 self locking nuts in scope of delivery Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550

Our Company Reviews