NJ40-FP-SN-P4 PEPPERL+FUCHS - Part number: 70133170
Out of Stock - Backorder
To order from manufacturer
USD392.52

Import Taxes Excluded

You must be logged

NJ40-FP-SN-P4 PEPPERL+FUCHS - Part number: 70133170

PEPPERL+FUCHS

Inductive sensor NJ40-FP-SN-P4 NJ40-FP-SN-P4 40 mm non-flush Inductive sensor NJ40-FP-SN-P4 NJ40-FP-SN-P4 40 mm non-flush

MPNs 70133170, PEP70133170, NJ40-FP-SN-P4
HS Code 85365090
Weight N/A

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

USD392.52

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of PEPPERL+FUCHS
Free express shipping to United States
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Request your tailored technical service

Rely on our expert technical team for a range of personalized services: repair, programming, maintenance, and much more.

Product information

Description

Datasheet excerpt: Technical data of  NJ40-FP-SN-P4 General specifications Switching functionNormally closed (NC) Output typeNAMUR with safety function Rated operating distance40 mm Installationnon-flush Assured operating distance0 ... 32.4 mm Reduction factor rAl 0.4 Reduction factor rCu 0.3 Reduction factor r304 0.85 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 100 Hz Current consumption Measuring plate not detectedmin. 3 mA Measuring plate detected≤ 1 mA Functional safety related parameters MTTFd7560 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GbIECEx PTB 11.0092X Equipment protection level DaIECEx PTB 11.0092X ATEX approval Equipment protection level GbPTB 00 ATEX 2049 X Equipment protection level DaPTB 00 ATEX 2049 X EAC conformityTR CU 012/2011 UL approvalcULus Listed, General Purpose KCC approval Hazardous Location18-AV4BO-0478X Ambient conditions Ambient temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection type1/2 NPT terminal compartment, wire cross-section ≤ 2.5 mm2 Core cross sectionup to 2.5 mm2 Housing materialPBT/metal Sensing facePBT Degree of protectionIP68 General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027272401 ECLASS 10.0.127272401 ECLASS 9.027272401 ECLASS 8.027272401 ECLASS 5.127272401 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  NJ40-FP-SN-P4 General specifications Switching functionNormally closed (NC) Output typeNAMUR with safety function Rated operating distance40 mm Installationnon-flush Assured operating distance0 ... 32.4 mm Reduction factor rAl 0.4 Reduction factor rCu 0.3 Reduction factor r304 0.85 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 100 Hz Current consumption Measuring plate not detectedmin. 3 mA Measuring plate detected≤ 1 mA Functional safety related parameters MTTFd7560 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GbIECEx PTB 11.0092X Equipment protection level DaIECEx PTB 11.0092X ATEX approval Equipment protection level GbPTB 00 ATEX 2049 X Equipment protection level DaPTB 00 ATEX 2049 X EAC conformityTR CU 012/2011 UL approvalcULus Listed, General Purpose KCC approval Hazardous Location18-AV4BO-0478X Ambient conditions Ambient temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection type1/2 NPT terminal compartment, wire cross-section ≤ 2.5 mm2 Core cross sectionup to 2.5 mm2 Housing materialPBT/metal Sensing facePBT Degree of protectionIP68 General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027272401 ECLASS 10.0.127272401 ECLASS 9.027272401 ECLASS 8.027272401 ECLASS 5.127272401 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550