SJ3,5-N-K37 PEPPERL+FUCHS - Part number: 70132990
Available on request

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

SJ3,5-N-K37 PEPPERL+FUCHS - Part number: 70132990

PEPPERL+FUCHS

Inductive slot sensor SJ3,5-N-K37 SJ3,5-N-K37 Comfort series NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers Inductive slot sensor SJ3,5-N-K37 SJ3,5-N-K37 Comfort series NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers

MPNs 70132990, PEP70132990, SJ3,5-N-K37
HS Code 85365090
Weight N/A

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Available on request

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

Datasheet excerpt: Technical data of  SJ3,5-N-K37 General specifications Switching functionNormally closed (NC) Output typeNAMUR Slot width3.5 mm Depth of immersion (lateral)5 ... 7 typ. 6 mm Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Operating voltage5 ... 25 V Switching frequency0 ... 3000 Hz Hysteresis0.41 ... 0.6 mm Current consumption Measuring plate not detected≥ 3 mA at nominal voltage Measuring plate detected≤ 1 mA at nominal voltage Functional safety related parameters MTTFd5270 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GbIECEx PTB 11.0091X Equipment protection level DaIECEx PTB 11.0091X Equipment protection level MbIECEx PTB 11.0091X ATEX approval Equipment protection level GbPTB 99 ATEX 2219 X Equipment protection level DaPTB 99 ATEX 2219 X UL approvalcULus Listed, General Purpose Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Mechanical specifications Connection typeflexible leads LiY Housing materialPBT Degree of protectionIP67 Cable Cable diameter1.1 mm ± 0.1 mm Bending radius> 10 x cable diameter MaterialPVC Core cross section0.14 mm2 Length500 mm General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 Datasheet excerpt: Technical data of  SJ3,5-N-K37 General specifications Switching functionNormally closed (NC) Output typeNAMUR Slot width3.5 mm Depth of immersion (lateral)5 ... 7 typ. 6 mm Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Operating voltage5 ... 25 V Switching frequency0 ... 3000 Hz Hysteresis0.41 ... 0.6 mm Current consumption Measuring plate not detected≥ 3 mA at nominal voltage Measuring plate detected≤ 1 mA at nominal voltage Functional safety related parameters MTTFd5270 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GbIECEx PTB 11.0091X Equipment protection level DaIECEx PTB 11.0091X Equipment protection level MbIECEx PTB 11.0091X ATEX approval Equipment protection level GbPTB 99 ATEX 2219 X Equipment protection level DaPTB 99 ATEX 2219 X UL approvalcULus Listed, General Purpose Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Mechanical specifications Connection typeflexible leads LiY Housing materialPBT Degree of protectionIP67 Cable Cable diameter1.1 mm ± 0.1 mm Bending radius> 10 x cable diameter MaterialPVC Core cross section0.14 mm2 Length500 mm General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714

Our Company Reviews