SJ3,5-S1N PEPPERL+FUCHS - Part number: 70133007
Out of Stock - Backorder
To order from manufacturer
USD162.54

Import Taxes Excluded

You must be logged

SJ3,5-S1N PEPPERL+FUCHS - Part number: 70133007

PEPPERL+FUCHS

Inductive slot sensor SJ3,5-S1N SJ3,5-S1N 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Nonferrous targets Inductive slot sensor SJ3,5-S1N SJ3,5-S1N 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Nonferrous targets

MPNs 70133007, PEP70133007, SJ3,5-S1N
HS Code 85365090
Weight N/A

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

USD162.54

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of PEPPERL+FUCHS
Free express shipping to United States
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

Datasheet excerpt: Technical data of  SJ3,5-S1N General specifications Switching functionNormally open (NO) Output typeNAMUR with safety function Slot width3.5 mm Depth of immersion (lateral)5 ... 7 typ. 6 mm Reference target10 x 7 x 0.3 mm3, Al Safety Integrity Level (SIL)up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation. Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 2500 Hz Hysteresiswith NAMUR switch amplifier: 0.09 mm (e. g. Pepperl+Fuchs KCD2-SR-Ex1.LB) with safety switch amplifier 0.05 mm (e. g. Pepperl+Fuchs KFD2-SH-Ex1) Suitable for 2:1 technologyyes , with reverse polarity protection diode Rate of current rise2.1 mA / mm Current consumption Measuring plate not detected0.2 ... 1 mA Measuring plate detected≥ 3 mA Functional safety related parameters Safety Integrity Level (SIL)SIL 3 MTTFd11850 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0092X Equipment protection level GbIECEx PTB 11.0092X Equipment protection level DaIECEx PTB 11.0092X Equipment protection level MbIECEx PTB 11.0092X ATEX approval Equipment protection level GaPTB 00 ATEX 2049 X Equipment protection level GbPTB 00 ATEX 2049 X Equipment protection level DaPTB 00 ATEX 2049 X EAC conformityTR CU 012/2011 UL approvalcULus Listed, General Purpose Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0454 CCC approval Hazardous Location2020322315002308 NEPSI approval NEPSI certificateGYJ16.1392X Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Mechanical specifications Connection typeflexible leads LiY Housing materialPBT Degree of protectionIP67 Cable Cable diameter1.1 mm ± 0.1 mm Bending radius> 10 x cable diameter MaterialPVC Core cross section0.14 mm2 Length500 mm Noteonly for non-ferrous metal Adjustable stop General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 Datasheet excerpt: Technical data of  SJ3,5-S1N General specifications Switching functionNormally open (NO) Output typeNAMUR with safety function Slot width3.5 mm Depth of immersion (lateral)5 ... 7 typ. 6 mm Reference target10 x 7 x 0.3 mm3, Al Safety Integrity Level (SIL)up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation. Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 2500 Hz Hysteresiswith NAMUR switch amplifier: 0.09 mm (e. g. Pepperl+Fuchs KCD2-SR-Ex1.LB) with safety switch amplifier 0.05 mm (e. g. Pepperl+Fuchs KFD2-SH-Ex1) Suitable for 2:1 technologyyes , with reverse polarity protection diode Rate of current rise2.1 mA / mm Current consumption Measuring plate not detected0.2 ... 1 mA Measuring plate detected≥ 3 mA Functional safety related parameters Safety Integrity Level (SIL)SIL 3 MTTFd11850 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0092X Equipment protection level GbIECEx PTB 11.0092X Equipment protection level DaIECEx PTB 11.0092X Equipment protection level MbIECEx PTB 11.0092X ATEX approval Equipment protection level GaPTB 00 ATEX 2049 X Equipment protection level GbPTB 00 ATEX 2049 X Equipment protection level DaPTB 00 ATEX 2049 X EAC conformityTR CU 012/2011 UL approvalcULus Listed, General Purpose Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0454 CCC approval Hazardous Location2020322315002308 NEPSI approval NEPSI certificateGYJ16.1392X Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Mechanical specifications Connection typeflexible leads LiY Housing materialPBT Degree of protectionIP67 Cable Cable diameter1.1 mm ± 0.1 mm Bending radius> 10 x cable diameter MaterialPVC Core cross section0.14 mm2 Length500 mm Noteonly for non-ferrous metal Adjustable stop General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714