订单满150欧元(最多10公斤)可享欧洲、美国和加拿大免费快递配送。
info
探索
-
Menu返回
-
品牌
-
- Technologies for:
-
Industry
-
-
- Automation
- Motors & Drives
- Safety
- Sensors
- Connect
- Signal Cables
- Weighing
- Valves & Controls
-
Industrial Plugs & Sockets
- Panel-mounted CEE socket outlet (IEC 60309)
- CEE coupling (IEC 60309)
- CEE plug (IEC 60309)
- CEE socket outlet combination (IEC 60309)
- CEE appliance inlet (IEC 60309)
- CEE socket outlet (IEC 60309)
- CEE socket outlet, disconnectable, with fuse (IEC 60309)
- 防爆CEE插座(IEC 60309)
- CEE 插头和插座附件/备件 (IEC 60309)
- 防爆 CEE 插头/耦合器 (IEC 60309)
- 防爆开关
- 测试与测量仪器附件和备件
- 能源监控
-
-
-
Building
-
-
- Green Power
- HVAC - Climatisation
- Lighting
- Monitor & Networking
- e-Mobility
-
Automation - Bus Systems
-
Control Elements
- Analogue input for bus system
- Basic module for bus system
- Binary input for bus system
- Central device for bus system
- Controller for home automation systems
- Display for bus system
- I/O device for bus system
- Logic component for bus system
- Signalling and operation panel for bus system
- Light control unit for bus system
- 总线系统室温控制器
- Sensors
- Actuators
- Bus Communications
- Programming
- Others
-
Control Elements
-
Domestic switching devices
- Socket outlet combinations
- Cover frames for domestic switching devices
- Mounting for labelling material
- Plug adapters
- Socket outlets
- Plugs with protective contact
- Inserts/covers for communication technology
- Installation switches
- Movement sensors/presence detectors complete
- Push buttons
- Control elements/cover plates for domestic switching devices
- USB power supplies
- Sensor elements for movement sensor
- 配电单元(PDU)
- Energy consumption indication
- Emergency call system devices
- 诊所安装系统设备
- Pluggable building installation systems
-
-
-
Electrification
-
-
- Cables
- Installation
-
Low Voltage
-
Cabinets & Enclosures
- Base/base element (enclosure/cabinet)
- Clima Control
- Door/operating panel (enclosure/cabinet)
- Electronic enclosure
- Empty cabinet
-
Energy distribution systems
- Accessories/spare parts for busbar trunks
- Accessories/spare parts for busbars
- Busbar couplers
- Busbar supports
- Busbar trunk units
- Cover caps for rail terminal bar
- Distributor assembly miniature circuit breakers (MCB)
- Distributor assembly terminal blocks
- Feed units for busbar trunk
- Main line branch terminals
- Meter cabinets equipped
- Mounting plates for distribution board
- Mounting rails
- Mounting systems for busbar trunk
- Phase barrier plates
- Tap off units for busbar trunk
- 小型配电箱
- 配电板面板
- 配电箱盖板
- Explosion proof enclosure/housing
- Front panel (enclosure/cabinet)
- Keys for enclosures/cabinets
- Lock systems for enclosure/cabinet
- Mounting accessories (enclosure/cabinet)
- Network cabinet
- Network/server enclosure
-
Circuit Breakers
- Auxiliary contact block
- Busbar adapters
- Device circuit breaker
- Earth leakage circuit breaker
- Fuse switch disconnector
- Fuses
- Main line circuit breaker
- Miniature circuit breaker (MCB)
- Off-load switches
-
Power Circuit Breakers
- Chassis part power circuit breaker
- Door coupling handles
- Handle for power circuit breaker
- Modification set for power circuit breaker
- Motor operator for power circuit-breaker
- Phase separation plate for power circuit breaker
- Shunt release (for power circuit breaker)
- Switch spool for power circuit breaker
- Trip block for power circuit-breaker
- Under voltage coil
- Wiring set for power circuit breaker
- Residual current circuit breaker (RCCB)
- Surge protection device for power supply systems
- Trip indicator
-
command devices (Buttons, selectors, indicators)
- Accessories/spare parts for command devices
- Accessories/spare parts for emergency stop pull cord switch
- Acoustic indicator
- Adapter for command devices
- Buttons
- Control circuit devices combination in enclosure
- Control switch, Joystick
- Emergency stop complete
- Emergency stop pull cord switch
- Enclosure for control circuit devices
- Foot switch
- Legend plate for control circuit devices
- Potentiometer for command devices
- Protective cap for command devices
- Selectors
- Signal towers
- Text plate for command devices
- Two-hand control device
- 指示灯 / 信号灯
- 指示灯 / 信号灯
- Contactors
- DIN 导轨适配器
- Filters for low-voltage
- Low Voltage Accessories
-
Motor start & protection
- Accessories/spare parts for electronic motor control and protection device
- Electronic overload relay
- Extension module for motor management device
- Motor management device
- Motor protection circuit-breaker
- Motor starter/motor starter combination
- Operator panel for Motor management device
- Soft starter
- Thermal overload relay
- Power supply
-
Relays
- (Fill) level monitoring relay
- Accessories/spare parts for switching relay
- Current monitoring relay
- Latching relay
- Optocoupler
- Relay socket
- Relays for thermistor protection (PTC)
- Residual current monitoring relay
- Residual current monitoring relay
- Solid state relay
- Speed-/standstill monitoring relay
- Speed-/standstill monitoring relay
- Switching relay
- Temperature monitoring relay
- Timer blocks
- Timer relay
- Voltage monitoring relay
- 安装继电器
- Surge protection module
- Switch disconnector (low voltage)
-
Terminal blocks
- (Knife) disconnect terminal block
- Accessories/spare parts for terminals
- Component plug terminal block
- Component terminal block
- Cross-connector for terminal block
- End bracket for terminal block
- Endplate and partition plate for terminal block
- Feed-through terminal block
- Fuse terminal block
- Ground terminal block
- Labelling for terminal block
- Multi level installation terminal block
- Sensor/actuator terminal block
- Shield connection clamp
- Single- and multi-pole terminal strip
- Terminal block connector
- Test plug for terminal blocks
- Transformers & coils
- 功率电容器
- 建筑工地用ASC配电箱
- 数据/信号线路浪涌保护
- 电池和电池模块
-
Cabinets & Enclosures
- Marking
- Optical and acoustic signalling
- UPS
-
-
-
Tools
-
- 联系我们
- 关于我们
- 促销
联系信息
-
PLC-City
Via Circumvallazione esterna 12
80025 Casandrino NA
意大利
Menu
-
Menu返回
-
品牌
-
- Technologies for:
-
Industry
-
-
- Automation
- Motors & Drives
- Safety
- Sensors
- Connect
- Signal Cables
- Weighing
- Valves & Controls
-
Industrial Plugs & Sockets
- Panel-mounted CEE socket outlet (IEC 60309)
- CEE coupling (IEC 60309)
- CEE plug (IEC 60309)
- CEE socket outlet combination (IEC 60309)
- CEE appliance inlet (IEC 60309)
- CEE socket outlet (IEC 60309)
- CEE socket outlet, disconnectable, with fuse (IEC 60309)
- 防爆CEE插座(IEC 60309)
- CEE 插头和插座附件/备件 (IEC 60309)
- 防爆 CEE 插头/耦合器 (IEC 60309)
- 防爆开关
- 测试与测量仪器附件和备件
- 能源监控
-
-
-
Building
-
-
- Green Power
- HVAC - Climatisation
- Lighting
- Monitor & Networking
- e-Mobility
-
Automation - Bus Systems
-
Control Elements
- Analogue input for bus system
- Basic module for bus system
- Binary input for bus system
- Central device for bus system
- Controller for home automation systems
- Display for bus system
- I/O device for bus system
- Logic component for bus system
- Signalling and operation panel for bus system
- Light control unit for bus system
- 总线系统室温控制器
- Sensors
- Actuators
- Bus Communications
- Programming
- Others
-
Control Elements
-
Domestic switching devices
- Socket outlet combinations
- Cover frames for domestic switching devices
- Mounting for labelling material
- Plug adapters
- Socket outlets
- Plugs with protective contact
- Inserts/covers for communication technology
- Installation switches
- Movement sensors/presence detectors complete
- Push buttons
- Control elements/cover plates for domestic switching devices
- USB power supplies
- Sensor elements for movement sensor
- 配电单元(PDU)
- Energy consumption indication
- Emergency call system devices
- 诊所安装系统设备
- Pluggable building installation systems
-
-
-
Electrification
-
-
- Cables
- Installation
-
Low Voltage
-
Cabinets & Enclosures
- Base/base element (enclosure/cabinet)
- Clima Control
- Door/operating panel (enclosure/cabinet)
- Electronic enclosure
- Empty cabinet
-
Energy distribution systems
- Accessories/spare parts for busbar trunks
- Accessories/spare parts for busbars
- Busbar couplers
- Busbar supports
- Busbar trunk units
- Cover caps for rail terminal bar
- Distributor assembly miniature circuit breakers (MCB)
- Distributor assembly terminal blocks
- Feed units for busbar trunk
- Main line branch terminals
- Meter cabinets equipped
- Mounting plates for distribution board
- Mounting rails
- Mounting systems for busbar trunk
- Phase barrier plates
- Tap off units for busbar trunk
- 小型配电箱
- 配电板面板
- 配电箱盖板
- Explosion proof enclosure/housing
- Front panel (enclosure/cabinet)
- Keys for enclosures/cabinets
- Lock systems for enclosure/cabinet
- Mounting accessories (enclosure/cabinet)
- Network cabinet
- Network/server enclosure
-
Circuit Breakers
- Auxiliary contact block
- Busbar adapters
- Device circuit breaker
- Earth leakage circuit breaker
- Fuse switch disconnector
- Fuses
- Main line circuit breaker
- Miniature circuit breaker (MCB)
- Off-load switches
-
Power Circuit Breakers
- Chassis part power circuit breaker
- Door coupling handles
- Handle for power circuit breaker
- Modification set for power circuit breaker
- Motor operator for power circuit-breaker
- Phase separation plate for power circuit breaker
- Shunt release (for power circuit breaker)
- Switch spool for power circuit breaker
- Trip block for power circuit-breaker
- Under voltage coil
- Wiring set for power circuit breaker
- Residual current circuit breaker (RCCB)
- Surge protection device for power supply systems
- Trip indicator
-
command devices (Buttons, selectors, indicators)
- Accessories/spare parts for command devices
- Accessories/spare parts for emergency stop pull cord switch
- Acoustic indicator
- Adapter for command devices
- Buttons
- Control circuit devices combination in enclosure
- Control switch, Joystick
- Emergency stop complete
- Emergency stop pull cord switch
- Enclosure for control circuit devices
- Foot switch
- Legend plate for control circuit devices
- Potentiometer for command devices
- Protective cap for command devices
- Selectors
- Signal towers
- Text plate for command devices
- Two-hand control device
- 指示灯 / 信号灯
- 指示灯 / 信号灯
- Contactors
- DIN 导轨适配器
- Filters for low-voltage
- Low Voltage Accessories
-
Motor start & protection
- Accessories/spare parts for electronic motor control and protection device
- Electronic overload relay
- Extension module for motor management device
- Motor management device
- Motor protection circuit-breaker
- Motor starter/motor starter combination
- Operator panel for Motor management device
- Soft starter
- Thermal overload relay
- Power supply
-
Relays
- (Fill) level monitoring relay
- Accessories/spare parts for switching relay
- Current monitoring relay
- Latching relay
- Optocoupler
- Relay socket
- Relays for thermistor protection (PTC)
- Residual current monitoring relay
- Residual current monitoring relay
- Solid state relay
- Speed-/standstill monitoring relay
- Speed-/standstill monitoring relay
- Switching relay
- Temperature monitoring relay
- Timer blocks
- Timer relay
- Voltage monitoring relay
- 安装继电器
- Surge protection module
- Switch disconnector (low voltage)
-
Terminal blocks
- (Knife) disconnect terminal block
- Accessories/spare parts for terminals
- Component plug terminal block
- Component terminal block
- Cross-connector for terminal block
- End bracket for terminal block
- Endplate and partition plate for terminal block
- Feed-through terminal block
- Fuse terminal block
- Ground terminal block
- Labelling for terminal block
- Multi level installation terminal block
- Sensor/actuator terminal block
- Shield connection clamp
- Single- and multi-pole terminal strip
- Terminal block connector
- Test plug for terminal blocks
- Transformers & coils
- 功率电容器
- 建筑工地用ASC配电箱
- 数据/信号线路浪涌保护
- 电池和电池模块
-
Cabinets & Enclosures
- Marking
- Optical and acoustic signalling
- UPS
-
-
-
Tools
-
- 联系我们
- 关于我们
- 促销
LVL-A7-AG1A-E5V1-CG..EMS PEPPERL+FUCHS - Part number: 275573-100021
PEPPERL+FUCHS
Vibration Limit Switch LVL-A7-AG1A-E5V1-CG-EMS LVL-A7-AG1A-E5V1-CG-EMS Limit switch for liquids Process connection G1/2 Suitable for process temperatures up to 100 °C (212 °F) Rugged stainless steel housing Onsite function check possible thanks to LED indication External function test with test magnet Vibration Limit Switch LVL-A7-AG1A-E5V1-CG-EMS LVL-A7-AG1A-E5V1-CG-EMS Limit switch for liquids Process connection G1/2 Suitable for process temperatures up to 100 °C (212 °F) Rugged stainless steel housing Onsite function check possible thanks to LED indication External function test with test magnet
MPNs 275573-100021, PEP275573-100021, LVL-A7-AG1A-E5V1-CG..EMS
税则号 85371000
Weight
0.14 kg
产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货
安全支付
等等
我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息
12个月 保修
本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
查看所有运输服务
Shipping:
到
的
Estimated delivery:
The selected carrier does not apply to this product
请求报价以知道交货日期
安全支付
等等
我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息
12个月 保修
本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固
产品信息
描述
Datasheet excerpt: Technical data of
LVL-A7-AG1A-E5V1-CG-EMS
General specifications
Measuring methodThe tuning fork is brought to its resonance frequency by means of a piezoelectric drive. If the tuning fork is covered by liquid, this frequency changes. The electronics monitor the resonance frequency and indicate whether the tuning fork is freely vibrating or is covered by liquid.
Construction typecompact device
Operating modeMAX = maximum safety:The device keeps the electronic switch closed as long as the liquid level is below the fork.example application: overspill protectionMIN = minimum safety:The device keeps the electronic switch closed as long as the fork is immersed in liquid.example application: dry running protection of pumpsThe electronic switch opens if the limit is reached, if a fault occurs or in the event of a power fails (quiescent current principle)
Supply
ConnectionThis device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements.
Rated voltage10 ... 35 V DC
Fusingexternal 500 mA slow
Current consumption< 15 mA
Power consumption975 mW
Residual ripple5 V ss at 0 ... 400 Hz
Input
Measured variabledensity
Measurement rangemin. 0.7 g/cm3
Output
Output typeswitch output
Switching currentmax. 250 mA
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2006 , EN 61326-2-3:2006
Directive 2004/108/ECEN 61326-1:2006 , EN 61326-2-3:2006
Conformity
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-64
Climate classDIN EN 60068-2-38/IEC 68-2-38
Measurement accuracy
Reference operating conditions- ambient temperature: 25 °C (+77 °F)- process pressure: 1 bar (14.5 psi)- fluid: water (density: 1 g/cm3, viscosity: 1 mm2/s)- medium temperature: 25 °C (+77 °F)- density setting: > 0.7 g/cm3- switching time delay: standard (0,5 s, 1 s)
Measured value resolution< 0.5 mm
Measuring frequency1100 Hz in air
Switching point13 mm ± 1 mm
Non-repeatability± 1 mm acc. to DIN 61298-2
Hysteresismax. 3 mm
Influence of ambient temperaturenegligible
Influence of medium temperature-25 µm/°C
Influence of medium pressure-20 µm/bar
Switching time- 0.5 s when tuning fork is covered- 1.0 s when tuning fork is uncovered
Switch-on delaymax. 3 s
Operating conditions
Installation conditions
Installation positionsee technical information (TI)
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Shock resistancea = 300 m/s2 = 30 g, 3 planes x 2 directions x 3 shocks x 18 ms, as per test Ea
Vibration resistancea(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h
Process conditions
Medium temperature-40 ... 100 °C (-40 ... 212 °F)
Process pressure (static pressure)-1 ... +40 bar (-14.5 ... +580 psi)
State of aggregationliquid
Densitymin. 0.7 g/cm3
Viscosity1 ... 10000 mPa/s, dynamic viscosity
Solid contents< ∅5 mm
Mechanical specifications
Degree of protectionIP65/IP67 , NEMA 4X
ConnectionM12 connector, 4-pin
Materialprocess connection and short tube: stainless steel 316L (1.4401/1.4435)tuning fork: stainless steel 316Lhousing cover and connector: PPSU
Surface qualityRa < 3.2 µm
Mass140 g
Process connectionthread G1/2 to ISO 228
Indication and operation
Display elementsThe LED display is on the connection side.- green LED: indication of ready to operate- red LED: fault indication- yellow LED: operating mode indication
Function testfunction test with test magnet (optional accessory)
Certificates and approvals
CSA approvalcCSAus Listed, General Purpose
Overspill protectionsee approval (ZE)
General information
Supplementary documentationtechnical information (TI) manual (BA) approval (ZE)
Supplementary informationStatement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Accessories
Designationsee technical information (TI)
Classifications
SystemClasscode
ECLASS 11.027200518
ECLASS 10.0.127200518
ECLASS 9.027200589
ECLASS 8.027200589
ECLASS 5.127200589
ETIM 8.0EC001447
ETIM 7.0EC001447
ETIM 6.0EC001447
ETIM 5.0EC001447
UNSPSC 12.141111950
Datasheet excerpt: Technical data of
LVL-A7-AG1A-E5V1-CG-EMS
General specifications
Measuring methodThe tuning fork is brought to its resonance frequency by means of a piezoelectric drive. If the tuning fork is covered by liquid, this frequency changes. The electronics monitor the resonance frequency and indicate whether the tuning fork is freely vibrating or is covered by liquid.
Construction typecompact device
Operating modeMAX = maximum safety:The device keeps the electronic switch closed as long as the liquid level is below the fork.example application: overspill protectionMIN = minimum safety:The device keeps the electronic switch closed as long as the fork is immersed in liquid.example application: dry running protection of pumpsThe electronic switch opens if the limit is reached, if a fault occurs or in the event of a power fails (quiescent current principle)
Supply
ConnectionThis device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements.
Rated voltage10 ... 35 V DC
Fusingexternal 500 mA slow
Current consumption< 15 mA
Power consumption975 mW
Residual ripple5 V ss at 0 ... 400 Hz
Input
Measured variabledensity
Measurement rangemin. 0.7 g/cm3
Output
Output typeswitch output
Switching currentmax. 250 mA
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2006 , EN 61326-2-3:2006
Directive 2004/108/ECEN 61326-1:2006 , EN 61326-2-3:2006
Conformity
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-64
Climate classDIN EN 60068-2-38/IEC 68-2-38
Measurement accuracy
Reference operating conditions- ambient temperature: 25 °C (+77 °F)- process pressure: 1 bar (14.5 psi)- fluid: water (density: 1 g/cm3, viscosity: 1 mm2/s)- medium temperature: 25 °C (+77 °F)- density setting: > 0.7 g/cm3- switching time delay: standard (0,5 s, 1 s)
Measured value resolution< 0.5 mm
Measuring frequency1100 Hz in air
Switching point13 mm ± 1 mm
Non-repeatability± 1 mm acc. to DIN 61298-2
Hysteresismax. 3 mm
Influence of ambient temperaturenegligible
Influence of medium temperature-25 µm/°C
Influence of medium pressure-20 µm/bar
Switching time- 0.5 s when tuning fork is covered- 1.0 s when tuning fork is uncovered
Switch-on delaymax. 3 s
Operating conditions
Installation conditions
Installation positionsee technical information (TI)
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Shock resistancea = 300 m/s2 = 30 g, 3 planes x 2 directions x 3 shocks x 18 ms, as per test Ea
Vibration resistancea(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h
Process conditions
Medium temperature-40 ... 100 °C (-40 ... 212 °F)
Process pressure (static pressure)-1 ... +40 bar (-14.5 ... +580 psi)
State of aggregationliquid
Densitymin. 0.7 g/cm3
Viscosity1 ... 10000 mPa/s, dynamic viscosity
Solid contents< ∅5 mm
Mechanical specifications
Degree of protectionIP65/IP67 , NEMA 4X
ConnectionM12 connector, 4-pin
Materialprocess connection and short tube: stainless steel 316L (1.4401/1.4435)tuning fork: stainless steel 316Lhousing cover and connector: PPSU
Surface qualityRa < 3.2 µm
Mass140 g
Process connectionthread G1/2 to ISO 228
Indication and operation
Display elementsThe LED display is on the connection side.- green LED: indication of ready to operate- red LED: fault indication- yellow LED: operating mode indication
Function testfunction test with test magnet (optional accessory)
Certificates and approvals
CSA approvalcCSAus Listed, General Purpose
Overspill protectionsee approval (ZE)
General information
Supplementary documentationtechnical information (TI) manual (BA) approval (ZE)
Supplementary informationStatement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Accessories
Designationsee technical information (TI)
Classifications
SystemClasscode
ECLASS 11.027200518
ECLASS 10.0.127200518
ECLASS 9.027200589
ECLASS 8.027200589
ECLASS 5.127200589
ETIM 8.0EC001447
ETIM 7.0EC001447
ETIM 6.0EC001447
ETIM 5.0EC001447
UNSPSC 12.141111950