ICA-10DI6DO-G60A-IO PEPPERL+FUCHS - Part number: 314644
缺货 - 延期交货
要从制造商订购
USD372.72

不含进口税

必须记录您

ICA-10DI6DO-G60A-IO PEPPERL+FUCHS - Part number: 314644

PEPPERL+FUCHS

I/O hub ICA-10DI6DO-G60A-IO ICA-10DI6DO-G60A-IO Sturdy metallic housing IO-link interface for service and process data 10 digital inputs and 6 digital outputs Logic level can be configured per port Filter time can be configured per port Pulse extension can be configured per port I/O hub ICA-10DI6DO-G60A-IO ICA-10DI6DO-G60A-IO Sturdy metallic housing IO-link interface for service and process data 10 digital inputs and 6 digital outputs Logic level can be configured per port Filter time can be configured per port Pulse extension can be configured per port

MPNs 314644, PEP314644, ICA-10DI6DO-G60A-IO
税则号 85371000
Weight 0.4 kg

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD372.72

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  ICA-10DI6DO-G60A-IO Product Description I/O hub with IO-Link interface for 10 digital inputs and 6 digital outputs General specifications UL File NumberE223772 Functional safety related parameters MTTFd2111 a Indicators/operating means LED UAUX Green: Actuator supply voltage OKRed: Actuator supply voltage < 18 V LED IO-LinkGreen: module is switched on, no communicationFlashing green: communication OKRed: signal line overload LED AOrange: status indicator channel A Red: peripheral error LED BWhite: status indicator channel B Red: peripheral error LED USGreen: system/sensor supply voltage OKRed: system/sensor supply voltage < 18 VFlashing red: sensor supply voltage overload Electrical specifications Rated operating voltage18 ... 30 V Nominal voltage24 V DC Nominal current4 A Current consumptiontyp. 80 mA Interface Interface typeIO-Link Device profileIdentification and Diagnosis - I&D Transfer rateCOM3 (230.4 kbits/s) IO-Link Revision1.1 Min. cycle time2 ms Process data widthInput 4 ByteOutput 4 Byte SIO mode supportno Device ID0x0F0202 (983554) Compatible master port typeB Input Number/Type10 digital inputs (X1 - X5) , 2-, 3-, 4-wire PNP, DC , Type 3 according to IEC 61131-2 Sensor supplyDepending on the IO-Link master, max. 500 mA per module Output Number/Type6 digital outputs (X6 - X8) , 2-, 3-wire connection Output rated operating currentDepending on the IO-Link master, max. 500 mA per channel Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardType 1 according to IEC 61131-2 Emitted interferenceEN 61000-6-2:2005 Noise immunityEN 61000-6-4:2007+A1:2011 Ambient conditions Ambient temperature-20 ... 70 °C (-4 ... 158 °F) Storage temperature-40 ... 70 °C (-40 ... 158 °F) Relative humiditymax. 95 % Altitude0 ... 2000 m Shock and impact resistance50 g, 11 ms, all axes Vibration resistance15 g / 5 ... 500 Hz Pollution degree3 Mechanical specifications Degree of protectionIP65/IP67/IP69K ConnectionPower supply/IO-Link M12, A-coded Inputs/Outputs M12, A-coded Material ContactsCuSn, gold-plated CuNi, gold-plated HousingDiecast zinc Plastic partsPA SealFKM Mass400 g Construction typeField housing Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001597 ETIM 7.0EC001597 ETIM 6.0EC001597 ETIM 5.0EC001597 UNSPSC 12.132151705 Datasheet excerpt: Technical data of  ICA-10DI6DO-G60A-IO Product Description I/O hub with IO-Link interface for 10 digital inputs and 6 digital outputs General specifications UL File NumberE223772 Functional safety related parameters MTTFd2111 a Indicators/operating means LED UAUX Green: Actuator supply voltage OKRed: Actuator supply voltage < 18 V LED IO-LinkGreen: module is switched on, no communicationFlashing green: communication OKRed: signal line overload LED AOrange: status indicator channel A Red: peripheral error LED BWhite: status indicator channel B Red: peripheral error LED USGreen: system/sensor supply voltage OKRed: system/sensor supply voltage < 18 VFlashing red: sensor supply voltage overload Electrical specifications Rated operating voltage18 ... 30 V Nominal voltage24 V DC Nominal current4 A Current consumptiontyp. 80 mA Interface Interface typeIO-Link Device profileIdentification and Diagnosis - I&D Transfer rateCOM3 (230.4 kbits/s) IO-Link Revision1.1 Min. cycle time2 ms Process data widthInput 4 ByteOutput 4 Byte SIO mode supportno Device ID0x0F0202 (983554) Compatible master port typeB Input Number/Type10 digital inputs (X1 - X5) , 2-, 3-, 4-wire PNP, DC , Type 3 according to IEC 61131-2 Sensor supplyDepending on the IO-Link master, max. 500 mA per module Output Number/Type6 digital outputs (X6 - X8) , 2-, 3-wire connection Output rated operating currentDepending on the IO-Link master, max. 500 mA per channel Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardType 1 according to IEC 61131-2 Emitted interferenceEN 61000-6-2:2005 Noise immunityEN 61000-6-4:2007+A1:2011 Ambient conditions Ambient temperature-20 ... 70 °C (-4 ... 158 °F) Storage temperature-40 ... 70 °C (-40 ... 158 °F) Relative humiditymax. 95 % Altitude0 ... 2000 m Shock and impact resistance50 g, 11 ms, all axes Vibration resistance15 g / 5 ... 500 Hz Pollution degree3 Mechanical specifications Degree of protectionIP65/IP67/IP69K ConnectionPower supply/IO-Link M12, A-coded Inputs/Outputs M12, A-coded Material ContactsCuSn, gold-plated CuNi, gold-plated HousingDiecast zinc Plastic partsPA SealFKM Mass400 g Construction typeField housing Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001597 ETIM 7.0EC001597 ETIM 6.0EC001597 ETIM 5.0EC001597 UNSPSC 12.132151705

公司评介