AS-Interface analog module VBA-2A-G11-IL-V1 VBA-2A-G11-IL-V1 Degree of protection IP68 / IP69K Function display for bus, external auxiliary voltage and outputs Power supply of outputs from the external auxiliary voltage Accuracy ± 0.15 % Integrated shielding Channel-specific output monitoring Communication monitoring AS-Interface analog module VBA-2A-G11-IL-V1 VBA-2A-G11-IL-V1 Degree of protection IP68 / IP69K Function display for bus, external auxiliary voltage and outputs Power supply of outputs from the external auxiliary voltage Accuracy ± 0.15 % Integrated shielding Channel-specific output monitoring Communication monitoring

MPNs 257493, PEP257493, VBA-2A-G11-IL-V1
税则号 85371091
Weight 0.2 kg

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD439.46

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  VBA-2A-G11-IL-V1 Product Description G11 analog module2 analog outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd365 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED AS-i/FAULTStatus display; multi-colour LEDGreen: normal operationRed: communication faultFlashing yellow/red: address 0Flashing green/red: peripheral fault LED ANALOGStatus of output signal; yellow LEDYellow: 0 mA ≤ I ≤ 23 mAYellow flashing: lead breakage or I > 23 mA LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 35 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Output Number/Type2 analog outputs (current), 0 ... 20 mA Supplyfrom AUX Loadmax. 600 Ω Current loading capacity≤ 700 mA (signal current + actuator supply) from external bulk power supply UAUX, overload and short-circuit protected Resolution6 µA Accuracy0.15 % of full-scale value Temperature influence1 µA/K Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, IEC 62026-2:2008 Programming instructions ProfileS-7.3.5 IO code7 ID code3 ID1 codeF ID2 code5 Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P0Watchdog:P0=1 (default), watchdog activeP0=0, watchdog inactive P1not used P2Indication of peripheral fault:P2=1 (default), peripheral fault is reportedP2=0, peripheral fault is not reported P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP68 / IP69K ConnectionAS-Interface/UAUX: M12 round connector Outputs: M12 round connector Material HousingPBT PC Mounting screwStainless steel 1.4305 / AISI 303 Mass200 g Tightening torque, housing screws1.8 Nm Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-2A-G11-IL-V1 Product Description G11 analog module2 analog outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd365 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED AS-i/FAULTStatus display; multi-colour LEDGreen: normal operationRed: communication faultFlashing yellow/red: address 0Flashing green/red: peripheral fault LED ANALOGStatus of output signal; yellow LEDYellow: 0 mA ≤ I ≤ 23 mAYellow flashing: lead breakage or I > 23 mA LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 35 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Output Number/Type2 analog outputs (current), 0 ... 20 mA Supplyfrom AUX Loadmax. 600 Ω Current loading capacity≤ 700 mA (signal current + actuator supply) from external bulk power supply UAUX, overload and short-circuit protected Resolution6 µA Accuracy0.15 % of full-scale value Temperature influence1 µA/K Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, IEC 62026-2:2008 Programming instructions ProfileS-7.3.5 IO code7 ID code3 ID1 codeF ID2 code5 Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P0Watchdog:P0=1 (default), watchdog activeP0=0, watchdog inactive P1not used P2Indication of peripheral fault:P2=1 (default), peripheral fault is reportedP2=0, peripheral fault is not reported P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP68 / IP69K ConnectionAS-Interface/UAUX: M12 round connector Outputs: M12 round connector Material HousingPBT PC Mounting screwStainless steel 1.4305 / AISI 303 Mass200 g Tightening torque, housing screws1.8 Nm Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535