VBA-4E-G11-I-F PEPPERL+FUCHS - Part number: 234280
缺货 - 延期交货
要从制造商订购
USD527.73

不含进口税

必须记录您

VBA-4E-G11-I-F PEPPERL+FUCHS - Part number: 234280

PEPPERL+FUCHS

AS-Interface analog module VBA-4E-G11-I-F VBA-4E-G11-I-F Addressing jack Function display for bus, internal and external sensor power supply, inputs Supply for inputs from AS-Interface or auxiliary voltage Degree of protection IP68 / IP69K Accuracy ± 0.1 % Integrated shielding Channel-specific input monitoring AS-Interface analog module VBA-4E-G11-I-F VBA-4E-G11-I-F Addressing jack Function display for bus, internal and external sensor power supply, inputs Supply for inputs from AS-Interface or auxiliary voltage Degree of protection IP68 / IP69K Accuracy ± 0.1 % Integrated shielding Channel-specific input monitoring

MPNs 234280, PEP234280, VBA-4E-G11-I-F
税则号 85371091
Weight 0.2 kg

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD527.73

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  VBA-4E-G11-I-F Product Description G11 analog module4 analog current inputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd180 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED AS-i/FAULTStatus display; multi-colour LEDGreen: normal operationRed: communication faultFlashing yellow/red: address 0Flashing green/red: peripheral fault LED ANALOGstatus of input signal; LED yellowoff: not activeon: signal within measurement rangeflashing: signal outside of measurement range LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INT/EXTstatus display input supply; LED greengreen: input supply from AS-Interfaceoff: input supply from auxiliary voltage Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 60 mA (without sensors) / max. 200 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 Inputs 0/4 ... 20 mA Supplyfrom AS-Interface (switch position INT, default settings) or auxiliary voltage UEXT (switch position EXT) Current loading capacity≤ 140 mA from AS-Interface; overload and short-circuit resistant ≤ 600 mA from external auxiliary voltage UAUX , overload and short-circuit protected Input resistancemax. 70 Ω Accuracy0.1 % of full-scale value Resolution16 Bit Temperature influence0.0025 %/K of input signal range Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.3.E IO code7 ID code3 ID1 codeF ID2 codeE Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P050/60 Hz filterP0=1, enabledP0=0, disabled P1not used P2Message of peripheral errorP2=1, peripheral error is reportedP2=0, peripheral error is not reported P3P3=1, wire break detection active, automatic channel detection (if > 1 mA)P3=0, wire break detection deactivated, all 4 channels active Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP68 / IP69K ConnectionAS-Interface/UAUX: cable piercing method, flat cable yellow/flat cable black Inputs: M12 round connector Material HousingPBT PC Mounting screwStainless steel 1.4305 / AISI 303 Mass200 g Tightening torque, housing screws1.8 Nm Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-4E-G11-I-F Product Description G11 analog module4 analog current inputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd180 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED AS-i/FAULTStatus display; multi-colour LEDGreen: normal operationRed: communication faultFlashing yellow/red: address 0Flashing green/red: peripheral fault LED ANALOGstatus of input signal; LED yellowoff: not activeon: signal within measurement rangeflashing: signal outside of measurement range LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INT/EXTstatus display input supply; LED greengreen: input supply from AS-Interfaceoff: input supply from auxiliary voltage Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 60 mA (without sensors) / max. 200 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 Inputs 0/4 ... 20 mA Supplyfrom AS-Interface (switch position INT, default settings) or auxiliary voltage UEXT (switch position EXT) Current loading capacity≤ 140 mA from AS-Interface; overload and short-circuit resistant ≤ 600 mA from external auxiliary voltage UAUX , overload and short-circuit protected Input resistancemax. 70 Ω Accuracy0.1 % of full-scale value Resolution16 Bit Temperature influence0.0025 %/K of input signal range Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.3.E IO code7 ID code3 ID1 codeF ID2 codeE Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P050/60 Hz filterP0=1, enabledP0=0, disabled P1not used P2Message of peripheral errorP2=1, peripheral error is reportedP2=0, peripheral error is not reported P3P3=1, wire break detection active, automatic channel detection (if > 1 mA)P3=0, wire break detection deactivated, all 4 channels active Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP68 / IP69K ConnectionAS-Interface/UAUX: cable piercing method, flat cable yellow/flat cable black Inputs: M12 round connector Material HousingPBT PC Mounting screwStainless steel 1.4305 / AISI 303 Mass200 g Tightening torque, housing screws1.8 Nm Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535

公司评介