OCT300-M1K-N2 PEPPERL+FUCHS - Part number: 106541
缺货 - 延期交货
要从制造商订购
USD684.23

不含进口税

必须记录您

OCT300-M1K-N2 PEPPERL+FUCHS - Part number: 106541

PEPPERL+FUCHS

Diffuse mode sensor, NAMUR OCT300-M1K-N2 OCT300-M1K-N2 ATEX-, IECEX approval for zone 20 (Dust) and zone 1 (Gas) Intrinsically safe, Ex op is ia IIC T6 Gb/IIIC T 135 °C Da Adjustable sensor head Scratch resistant mineral glass lens Diffuse mode sensor, NAMUR OCT300-M1K-N2 OCT300-M1K-N2 ATEX-, IECEX approval for zone 20 (Dust) and zone 1 (Gas) Intrinsically safe, Ex op is ia IIC T6 Gb/IIIC T 135 °C Da Adjustable sensor head Scratch resistant mineral glass lens

MPNs 106541, PEP106541, OCT300-M1K-N2
税则号 85365000
Weight 0.1 kg

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD684.23

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  OCT300-M1K-N2 Product Description Diffuse mode sensor, NAMUR, special design, 300 mm detection range, infrared light, light/dark on, DC version, NAMUR output, terminal compartment General specifications Detection range0 ... 300 mm Adjustment range70 ... 300 mm Reference targetstandard white 200 mm x 200 mm Light sourceIRED , 880 nm Light typemodulated infrared light Ambient light limit≤ 40000 Lux sun light ≤ 30000 Lux halogen light Temperature influence≤ 0.5 mm/K Functional safety related parameters MTTFd1319 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Function indicatorLED yellow: switching state Control elementsSensing range adjuster Electrical specifications Operating voltage6 ... 20 V DC (Ri 0 Ohm) Ripple5 % Time delay before availability20 ms Output Switching typelight/dark on, programmable Signal output1 NAMUR output NC/NO programmable Switching voltage8 V DC (Ri 1 kΩ) Switching frequency≤ 100 Hz Current consumption Reference target detectedconnection 1, 2: ≤ 1 mA connection 3, 4: ≥ 2.7 mA Reference target not detectedconnection 1, 2: ≥ 2.7 mA connection 3, 4: ≤ 1 mA Response time5 ms Repeat accuracy≤ 0.5 % of the sensing range Conformity Product standardEN 60947-5-2 Compliance with standards and directives Standard conformity StandardsEN 60947-5-6:2000 Approvals and certificates FM approval Approved forIS / I,II,III / 1 / ABCDEFG / T5 - 116-0110; EntityNI / I / 2 / ABCD / T6Entity Parameters:VMax = 12.6 V, IMax = 20 mA, Ci = 1.11 µF, Li = 0 mH (Groups A, B, C, D, E, F, G).VMax = 15.5 V, IMax = 52 mA, Ci = 1.11 µF, Li = 0 mH (Groups C, D, E, F, G). CSA approval Approved forClass I, Division 2, Groups A, B, C and DRated 20V (max), 50mA.These sensors are suitable for installation in (or through the wall of) a suitable enclosure with provision for connection of rigid metal conduit, as acceptable to the local inspection authority having jurisdiction. CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 80 °C (-40 ... 176 °F) Mechanical specifications Housing width30 mm Housing height30 mm Housing depth102 mm Degree of protectionIP67 ConnectionM16 terminal compartment, core cross section ≤ 2.5 mm2 Material HousingPBT Optical faceScratch resistant mineral glass lens Mass100 g ATEX G EC-Type Examination CertificatePTB 01 ATEX 2203 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany CE markingCE0102 ATEX markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb Directive conformity2014/34/EU StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 Effective internal capacitance Cimax. 75 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. ATEX D EC-Type Examination CertificateZELM 03 ATEX 0196 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany CE markingCE0102 ATEX markingZone 20/21: II 1D Ex ia IIIC T 135°C Da Directive conformity2014/34/EU StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 Effective internal capacitance Cimax. 1200 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection against dangerous electrostatic chargingThe device must be installed such that electrostatic discharges can be avoided. If the device is installed in accordance with the instructions provided by the manufacturer, no dangerous electrostatic charge is to be expected given the properties of the device. Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the surface temperature class. In applications where high levels of charge are expected (e.g. electrostatic paint, foil manufacture, dust extraction, mechanical friction), structural measures must be taken to limit the surface area of the plastic housing exposed to this charge to approximately 15 cm2 in order to avoid propagating brush discharge. When setting up a partition between different zones, appropriate measures must be taken to ensure that the components installed in the partition isolate the zones completely from one another. IECEx G Certificate numberIECEx PTB 12.0060 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany IECEx markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb StandardsIEC 60079-0:2011 IEC 60079-11:2011 IEC 60079-28:2006 Effective internal capacitance Cimax. 75 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. IECEx D Certificate numberIECEx ZLM 12.0005X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany IECEx markingEx ia IIIC T135°C Da StandardsIEC 60079-0:2011 IEC 60079-11:2011 Effective internal capacitance Cimax. 1200 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection against dangerous electrostatic chargingThe device must be installed such that electrostatic discharges can be avoided. If the device is installed in accordance with the instructions provided by the manufacturer, no dangerous electrostatic charge is to be expected given the properties of the device. Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsWhen setting up a partition between different zones, appropriate measures must be taken to ensure that the components installed in the partition isolate the zones completely from one another. Classifications SystemClasscode ECLASS 11.027270903 ECLASS 10.0.127270903 ECLASS 9.027270903 ECLASS 8.027270903 ECLASS 5.127270903 ETIM 8.0EC001821 ETIM 7.0EC001821 ETIM 6.0EC001821 ETIM 5.0EC001821 UNSPSC 12.139121528 Datasheet excerpt: Technical data of  OCT300-M1K-N2 Product Description Diffuse mode sensor, NAMUR, special design, 300 mm detection range, infrared light, light/dark on, DC version, NAMUR output, terminal compartment General specifications Detection range0 ... 300 mm Adjustment range70 ... 300 mm Reference targetstandard white 200 mm x 200 mm Light sourceIRED , 880 nm Light typemodulated infrared light Ambient light limit≤ 40000 Lux sun light ≤ 30000 Lux halogen light Temperature influence≤ 0.5 mm/K Functional safety related parameters MTTFd1319 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Function indicatorLED yellow: switching state Control elementsSensing range adjuster Electrical specifications Operating voltage6 ... 20 V DC (Ri 0 Ohm) Ripple5 % Time delay before availability20 ms Output Switching typelight/dark on, programmable Signal output1 NAMUR output NC/NO programmable Switching voltage8 V DC (Ri 1 kΩ) Switching frequency≤ 100 Hz Current consumption Reference target detectedconnection 1, 2: ≤ 1 mA connection 3, 4: ≥ 2.7 mA Reference target not detectedconnection 1, 2: ≥ 2.7 mA connection 3, 4: ≤ 1 mA Response time5 ms Repeat accuracy≤ 0.5 % of the sensing range Conformity Product standardEN 60947-5-2 Compliance with standards and directives Standard conformity StandardsEN 60947-5-6:2000 Approvals and certificates FM approval Approved forIS / I,II,III / 1 / ABCDEFG / T5 - 116-0110; EntityNI / I / 2 / ABCD / T6Entity Parameters:VMax = 12.6 V, IMax = 20 mA, Ci = 1.11 µF, Li = 0 mH (Groups A, B, C, D, E, F, G).VMax = 15.5 V, IMax = 52 mA, Ci = 1.11 µF, Li = 0 mH (Groups C, D, E, F, G). CSA approval Approved forClass I, Division 2, Groups A, B, C and DRated 20V (max), 50mA.These sensors are suitable for installation in (or through the wall of) a suitable enclosure with provision for connection of rigid metal conduit, as acceptable to the local inspection authority having jurisdiction. CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 80 °C (-40 ... 176 °F) Mechanical specifications Housing width30 mm Housing height30 mm Housing depth102 mm Degree of protectionIP67 ConnectionM16 terminal compartment, core cross section ≤ 2.5 mm2 Material HousingPBT Optical faceScratch resistant mineral glass lens Mass100 g ATEX G EC-Type Examination CertificatePTB 01 ATEX 2203 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany CE markingCE0102 ATEX markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb Directive conformity2014/34/EU StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 Effective internal capacitance Cimax. 75 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. ATEX D EC-Type Examination CertificateZELM 03 ATEX 0196 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany CE markingCE0102 ATEX markingZone 20/21: II 1D Ex ia IIIC T 135°C Da Directive conformity2014/34/EU StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 Effective internal capacitance Cimax. 1200 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection against dangerous electrostatic chargingThe device must be installed such that electrostatic discharges can be avoided. If the device is installed in accordance with the instructions provided by the manufacturer, no dangerous electrostatic charge is to be expected given the properties of the device. Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the surface temperature class. In applications where high levels of charge are expected (e.g. electrostatic paint, foil manufacture, dust extraction, mechanical friction), structural measures must be taken to limit the surface area of the plastic housing exposed to this charge to approximately 15 cm2 in order to avoid propagating brush discharge. When setting up a partition between different zones, appropriate measures must be taken to ensure that the components installed in the partition isolate the zones completely from one another. IECEx G Certificate numberIECEx PTB 12.0060 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany IECEx markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb StandardsIEC 60079-0:2011 IEC 60079-11:2011 IEC 60079-28:2006 Effective internal capacitance Cimax. 75 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. IECEx D Certificate numberIECEx ZLM 12.0005X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany IECEx markingEx ia IIIC T135°C Da StandardsIEC 60079-0:2011 IEC 60079-11:2011 Effective internal capacitance Cimax. 1200 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection against dangerous electrostatic chargingThe device must be installed such that electrostatic discharges can be avoided. If the device is installed in accordance with the instructions provided by the manufacturer, no dangerous electrostatic charge is to be expected given the properties of the device. Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsWhen setting up a partition between different zones, appropriate measures must be taken to ensure that the components installed in the partition isolate the zones completely from one another. Classifications SystemClasscode ECLASS 11.027270903 ECLASS 10.0.127270903 ECLASS 9.027270903 ECLASS 8.027270903 ECLASS 5.127270903 ETIM 8.0EC001821 ETIM 7.0EC001821 ETIM 6.0EC001821 ETIM 5.0EC001821 UNSPSC 12.139121528

公司评介