OQT400-R201-2EP-IO-0,3M-V31 PEPPERL+FUCHS - Part number: 295670-100168
缺货 - 延期交货
要从制造商订购
USD289.82

不含进口税

必须记录您

OQT400-R201-2EP-IO-0,3M-V31 PEPPERL+FUCHS - Part number: 295670-100168

PEPPERL+FUCHS

Triangulation sensor (SbR) OQT400-R201-2EP-IO-0,3M-V31 OQT400-R201-2EP-IO-0,3M-V31 Medium design with versatile mounting options Multi Pixel Technology (MPT) - flexibility and adaptability Reduction of device variety - several switch points within one sensor Reliable detection of all surfaces, independent of color and structure Low sensitivity to target color IO-Link interface for service and process data Triangulation sensor (SbR) OQT400-R201-2EP-IO-0,3M-V31 OQT400-R201-2EP-IO-0,3M-V31 Medium design with versatile mounting options Multi Pixel Technology (MPT) - flexibility and adaptability Reduction of device variety - several switch points within one sensor Reliable detection of all surfaces, independent of color and structure Low sensitivity to target color IO-Link interface for service and process data

MPNs 295670-100168, PEP295670-100168, OQT400-R201-2EP-IO-0,3M-V31
税则号 85365000
Weight N/A

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD289.82

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

产品信息

描述

Datasheet excerpt: Technical data of  OQT400-R201-2EP-IO-0,3M-V31 Product Description Measuring sensor with multiple switch points General specifications Detection range40 ... 400 mm Detection range min.40 ... 100 mm Detection range max.40 ... 400 mm Adjustment range100 ... 400 mm Reference targetstandard white, 100 mm x 100 mm Light sourceLED Light typemodulated visible red light LED risk group labellingexempt group Black-white difference (6 %/90 %)< 5 % Diameter of the light spot15 mm at a distance of 400 mm Opening angle2.5 ° Ambient light limitEN 60947-5-2 : 70000 Lux Functional safety related parameters MTTFd600 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Operation indicatorLED green:constantly on - power onflashing (4Hz) - short circuitflashing with short break (1 Hz) - IO-Link mode Function indicatorLED yellow:constantly on - switch output activeconstantly off - switch output inactive Control elementsTeach-In key Control elements5-step rotary switch for operating modes selection Electrical specifications Operating voltage10 ... 30 V DC Ripplemax. 10 % No-load supply current< 25 mA at 24 V supply voltage Protection classIII Interface Interface typeIO-Link ( via C/Q = pin 4 ) IO-Link revision1.1 Device profileIdentification and diagnosisSmart Sensor type 0 Device ID0x111811 (1120273) Transfer rateCOM2 (38.4 kBit/s) Min. cycle time2.3 ms Process data widthProcess data input 2 BitProcess data output 2 Bit SIO mode supportyes Compatible master port typeA Output Switching typeThe default setting is: C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link Q2 - Pin2: NPN normally-open, PNP normally-closed Signal output2 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity protected, overvoltage protected Switching voltagemax. 30 V DC Switching currentmax. 100 mA , resistive load Usage categoryDC-12 and DC-13 Voltage drop≤ 1.5 V DC Switching frequency217 Hz Response time2.3 ms Conformity Communication interfaceIEC 61131-9 Product standardEN 60947-5-2 Approvals and certificates EAC conformityTR CU 020/2011 UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1 CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-40 ... 60 °C (-40 ... 140 °F) , fixed cable -20 ... 60 °C (-4 ... 140 °F) , movable cable not appropriate for conveyor chains Storage temperature-40 ... 70 °C (-40 ... 158 °F) Mechanical specifications Housing width15 mm Housing height61.7 mm Housing depth41.7 mm Degree of protectionIP67 / IP69 / IP69K Connectionfixed cable 300 mm with M8 x 1 male connector; 4-pin Material HousingPC (Polycarbonate) Optical facePMMA Mass51 g Cable length0.3 m Classifications SystemClasscode ECLASS 11.027270903 ECLASS 10.0.127270903 ECLASS 9.027270903 ECLASS 8.027270903 ECLASS 5.127270903 ETIM 8.0EC001821 ETIM 7.0EC001821 ETIM 6.0EC001821 ETIM 5.0EC001821 UNSPSC 12.139121528 Datasheet excerpt: Technical data of  OQT400-R201-2EP-IO-0,3M-V31 Product Description Measuring sensor with multiple switch points General specifications Detection range40 ... 400 mm Detection range min.40 ... 100 mm Detection range max.40 ... 400 mm Adjustment range100 ... 400 mm Reference targetstandard white, 100 mm x 100 mm Light sourceLED Light typemodulated visible red light LED risk group labellingexempt group Black-white difference (6 %/90 %)< 5 % Diameter of the light spot15 mm at a distance of 400 mm Opening angle2.5 ° Ambient light limitEN 60947-5-2 : 70000 Lux Functional safety related parameters MTTFd600 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Operation indicatorLED green:constantly on - power onflashing (4Hz) - short circuitflashing with short break (1 Hz) - IO-Link mode Function indicatorLED yellow:constantly on - switch output activeconstantly off - switch output inactive Control elementsTeach-In key Control elements5-step rotary switch for operating modes selection Electrical specifications Operating voltage10 ... 30 V DC Ripplemax. 10 % No-load supply current< 25 mA at 24 V supply voltage Protection classIII Interface Interface typeIO-Link ( via C/Q = pin 4 ) IO-Link revision1.1 Device profileIdentification and diagnosisSmart Sensor type 0 Device ID0x111811 (1120273) Transfer rateCOM2 (38.4 kBit/s) Min. cycle time2.3 ms Process data widthProcess data input 2 BitProcess data output 2 Bit SIO mode supportyes Compatible master port typeA Output Switching typeThe default setting is: C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link Q2 - Pin2: NPN normally-open, PNP normally-closed Signal output2 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity protected, overvoltage protected Switching voltagemax. 30 V DC Switching currentmax. 100 mA , resistive load Usage categoryDC-12 and DC-13 Voltage drop≤ 1.5 V DC Switching frequency217 Hz Response time2.3 ms Conformity Communication interfaceIEC 61131-9 Product standardEN 60947-5-2 Approvals and certificates EAC conformityTR CU 020/2011 UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1 CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-40 ... 60 °C (-40 ... 140 °F) , fixed cable -20 ... 60 °C (-4 ... 140 °F) , movable cable not appropriate for conveyor chains Storage temperature-40 ... 70 °C (-40 ... 158 °F) Mechanical specifications Housing width15 mm Housing height61.7 mm Housing depth41.7 mm Degree of protectionIP67 / IP69 / IP69K Connectionfixed cable 300 mm with M8 x 1 male connector; 4-pin Material HousingPC (Polycarbonate) Optical facePMMA Mass51 g Cable length0.3 m Classifications SystemClasscode ECLASS 11.027270903 ECLASS 10.0.127270903 ECLASS 9.027270903 ECLASS 8.027270903 ECLASS 5.127270903 ETIM 8.0EC001821 ETIM 7.0EC001821 ETIM 6.0EC001821 ETIM 5.0EC001821 UNSPSC 12.139121528

公司评介