RLK28-55-Z/31/116 PEPPERL+FUCHS - Part number: 134130
缺货 - 延期交货
要从制造商订购
USD572.44

不含进口税

必须记录您

RLK28-55-Z/31/116 PEPPERL+FUCHS - Part number: 134130

PEPPERL+FUCHS

Retroreflective sensor RLK28-55-Z/31/116 RLK28-55-Z/31/116 Universal series with highly versatile fields of use Resistant against noise: reliable operation under all conditions Programmable time function GAN, GAB, IAB, as well as GAN-GAB and GAN-IAB as double function Version with red light Version with relay output Retroreflective sensor RLK28-55-Z/31/116 RLK28-55-Z/31/116 Universal series with highly versatile fields of use Resistant against noise: reliable operation under all conditions Programmable time function GAN, GAB, IAB, as well as GAN-GAB and GAN-IAB as double function Version with red light Version with relay output

MPNs 134130, PEP134130, RLK28-55-Z/31/116
税则号 85365090
Weight 0.11 kg

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD572.44

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  RLK28-55-Z/31/116 Product Description Retroreflective sensor with polarization filter General specifications Effective detection range0 ... 17 m Reflector distance0.05 ... 17 m Threshold detection range21 m Reference targetH85-2 reflector Light sourceLED Light typemodulated visible red light Polarization filteryes Diameter of the light spot290 mm at a distance of 17 m Opening angleemitter 1.2°receiver 2° Ambient light limit80000 Lux Functional safety related parameters MTTFd600 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Operation indicatorLED green Function indicator2 LEDs yellow, light up when light beam is free, flash when falling short of the stability control, off when light beam is interrupted Control elementssensitivity adjustment (Adjustment to < 25% of the effective operating range) , Light-on/dark-on changeover switch Electrical specifications Operating voltage12 ... 240 V AC/DC Power consumption≤ 3.5 VA Output Switching typelight/dark on switchable Signal outputRelay, 1 alternator Switching voltagemax. 250 V AC/DC Switching currentmax. 2 A Switching powerDC: max. 50 W AC: max. 500 VA Switching frequency25 Hz Response time20 ms Timer functionON delay (GAN), OFF delay (GAB), one shot (IAB), ON delay-one shot (GAN-IAB), ON delay-OFF delay (GAN-GAB), programmableadjustment interval 0.1 ... 10 s Conformity Product standardEN 60947-5-2 Approvals and certificates EAC conformityTR CU 020/2011 TR CU 004/2011 Protection classII, rated insulation voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit insulated from control circuit in accordance with IEC 61140.Caution!The protection class 2 is only valid when the terminal compartment is closed. UL approvalE87056 , cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508. CCC approvalCertified by China Compulsory Certification (CCC) Ambient conditions Ambient temperature-40 ... 60 °C (-40 ... 140 °F) Storage temperature-40 ... 75 °C (-40 ... 167 °F) Mechanical specifications Housing width25.8 mm Housing height88 mm Housing depth65.5 mm Degree of protectionIP67 Connectionterminal compartment with 8 spring-loaded terminals for wire cross section 0.5 ... 1.5 mm2 , Insulation stripping 7.5 ... 8.5 mm , M16 x 1.5 cable gland Material HousingPlastic ABS Optical facePlastic pane Mass112 g Classifications SystemClasscode ECLASS 11.027270902 ECLASS 10.0.127270902 ECLASS 9.027270902 ECLASS 8.027270902 ECLASS 5.127270902 ETIM 8.0EC002717 ETIM 7.0EC002717 ETIM 6.0EC002717 ETIM 5.0EC002717 UNSPSC 12.139121528 Datasheet excerpt: Technical data of  RLK28-55-Z/31/116 Product Description Retroreflective sensor with polarization filter General specifications Effective detection range0 ... 17 m Reflector distance0.05 ... 17 m Threshold detection range21 m Reference targetH85-2 reflector Light sourceLED Light typemodulated visible red light Polarization filteryes Diameter of the light spot290 mm at a distance of 17 m Opening angleemitter 1.2°receiver 2° Ambient light limit80000 Lux Functional safety related parameters MTTFd600 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Operation indicatorLED green Function indicator2 LEDs yellow, light up when light beam is free, flash when falling short of the stability control, off when light beam is interrupted Control elementssensitivity adjustment (Adjustment to < 25% of the effective operating range) , Light-on/dark-on changeover switch Electrical specifications Operating voltage12 ... 240 V AC/DC Power consumption≤ 3.5 VA Output Switching typelight/dark on switchable Signal outputRelay, 1 alternator Switching voltagemax. 250 V AC/DC Switching currentmax. 2 A Switching powerDC: max. 50 W AC: max. 500 VA Switching frequency25 Hz Response time20 ms Timer functionON delay (GAN), OFF delay (GAB), one shot (IAB), ON delay-one shot (GAN-IAB), ON delay-OFF delay (GAN-GAB), programmableadjustment interval 0.1 ... 10 s Conformity Product standardEN 60947-5-2 Approvals and certificates EAC conformityTR CU 020/2011 TR CU 004/2011 Protection classII, rated insulation voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit insulated from control circuit in accordance with IEC 61140.Caution!The protection class 2 is only valid when the terminal compartment is closed. UL approvalE87056 , cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508. CCC approvalCertified by China Compulsory Certification (CCC) Ambient conditions Ambient temperature-40 ... 60 °C (-40 ... 140 °F) Storage temperature-40 ... 75 °C (-40 ... 167 °F) Mechanical specifications Housing width25.8 mm Housing height88 mm Housing depth65.5 mm Degree of protectionIP67 Connectionterminal compartment with 8 spring-loaded terminals for wire cross section 0.5 ... 1.5 mm2 , Insulation stripping 7.5 ... 8.5 mm , M16 x 1.5 cable gland Material HousingPlastic ABS Optical facePlastic pane Mass112 g Classifications SystemClasscode ECLASS 11.027270902 ECLASS 10.0.127270902 ECLASS 9.027270902 ECLASS 8.027270902 ECLASS 5.127270902 ETIM 8.0EC002717 ETIM 7.0EC002717 ETIM 6.0EC002717 ETIM 5.0EC002717 UNSPSC 12.139121528

公司评介