PMI120-F90-IU2EP-IO-V15-3G-3D PEPPERL+FUCHS - Part number: 70126067
可应要求

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

PMI120-F90-IU2EP-IO-V15-3G-3D PEPPERL+FUCHS - Part number: 70126067

PEPPERL+FUCHS

Inductive positioning system PMI120-F90-IU2EP-IO-V15-3G-3D PMI120-F90-IU2EP-IO-V15-3G-3D Parameterization and diagnosis via IO-Link Measuring range 0 ... 120 mm Parameterisable measuring range Analog current or voltage output, programmable 2 Push-pull outputs Switch points programmable via IO-Link Inductive positioning system PMI120-F90-IU2EP-IO-V15-3G-3D PMI120-F90-IU2EP-IO-V15-3G-3D Parameterization and diagnosis via IO-Link Measuring range 0 ... 120 mm Parameterisable measuring range Analog current or voltage output, programmable 2 Push-pull outputs Switch points programmable via IO-Link

MPNs 70126067, PEP70126067, PMI120-F90-IU2EP-IO-V15-3G-3D
税则号 85219000
Weight 0.11 kg

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

可应要求

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  PMI120-F90-IU2EP-IO-V15-3G-3D General specifications Switching element functionAnalog current or voltage output, programmable 2 switch outputs, programmable Object distance0.5 ... 3 mm , recommended: 1.5 mm Measurement range0 ... 120 mm Linearity range1 ... 119 mm Nominal ratings Operating voltage12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized) Reverse polarity protectionreverse polarity protected Linearity errorwithin measuring range: ± 0.8 mm within linearity range: ± 0.4 mm Repeat accuracy± 0.1 mm Resolution50 µm Temperature drift± 0.5 mm (-25 °C ... 70 °C) No-load supply current≤ 40 mA Operating voltage indicatorLED green Functional safety related parameters MTTFd278 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED S1switching state Switching output 1 LED S2switching state Switching output 2 LED S3Damping element in the configured analog measuring range LED STATUSStatus display LED, green/red (Power on, communication/error, missing damping element) Interface Interface typeIO-Link (via C/Q = Pin 4) IO-Link revision1.1 Device profileSmart Sensor Device ID0x200404 (2098180) Transfer rateCOM2 (38.4 kBit/s) Value range0000h ... 9600h Min. cycle time2.3 ms Process data widthProcess data input: 16 Bit Process data output: none SIO mode supportyes Compatible master port typeA Switching output Output type2 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection, surge-proof Operating current≤ 100 mA / Output Switching window± 1 mm Switching hysteresis0.2 mm Voltage drop≤ 3 V Short-circuit protectionpulsing Analog output Output type1 current output: 4 ... 20 mA or 1 voltage output: 0 ... 10 V , programmable Load resistorcurrent output: ≤ 400 Ω voltage output: ≥ 1000 Ω Short-circuit protectionvoltage output: current limit Compliance with standards and directives Standard conformity StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 EN 60947-5-7:2003 EN61131-9:2013 IEC 60947-5-7:2003 IEC 61131-9:2013 Approvals and certificates IECEx approval Equipment protection level Gc (ec)IECEx TUR 21.0019X Equipment protection level Dc (tc)IECEx TUR 21.0020X ATEX approval Equipment protection level Gc (ec)TÜV 20 ATEX 8525 X Equipment protection level Dc (tc)TÜV 20 ATEX 8526 X UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure Marine approvalDNVGL TAA00001V2 Ambient conditions Ambient temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Connection type5-pin, M12 x 1 connector Degree of protectionIP67 / IP69K Material HousingPBT, stainless steel 1.4571 , brass, nickel-plated Targetmild steel, e. g. 1.0037, SR235JR (formerly St37-2) Mass113 g General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270702 ECLASS 10.0.127270702 ECLASS 9.027270702 ECLASS 8.027270702 ECLASS 5.127270702 ETIM 8.0EC001852 ETIM 7.0EC001852 ETIM 6.0EC001852 ETIM 5.0EC001852 Datasheet excerpt: Technical data of  PMI120-F90-IU2EP-IO-V15-3G-3D General specifications Switching element functionAnalog current or voltage output, programmable 2 switch outputs, programmable Object distance0.5 ... 3 mm , recommended: 1.5 mm Measurement range0 ... 120 mm Linearity range1 ... 119 mm Nominal ratings Operating voltage12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized) Reverse polarity protectionreverse polarity protected Linearity errorwithin measuring range: ± 0.8 mm within linearity range: ± 0.4 mm Repeat accuracy± 0.1 mm Resolution50 µm Temperature drift± 0.5 mm (-25 °C ... 70 °C) No-load supply current≤ 40 mA Operating voltage indicatorLED green Functional safety related parameters MTTFd278 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED S1switching state Switching output 1 LED S2switching state Switching output 2 LED S3Damping element in the configured analog measuring range LED STATUSStatus display LED, green/red (Power on, communication/error, missing damping element) Interface Interface typeIO-Link (via C/Q = Pin 4) IO-Link revision1.1 Device profileSmart Sensor Device ID0x200404 (2098180) Transfer rateCOM2 (38.4 kBit/s) Value range0000h ... 9600h Min. cycle time2.3 ms Process data widthProcess data input: 16 Bit Process data output: none SIO mode supportyes Compatible master port typeA Switching output Output type2 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection, surge-proof Operating current≤ 100 mA / Output Switching window± 1 mm Switching hysteresis0.2 mm Voltage drop≤ 3 V Short-circuit protectionpulsing Analog output Output type1 current output: 4 ... 20 mA or 1 voltage output: 0 ... 10 V , programmable Load resistorcurrent output: ≤ 400 Ω voltage output: ≥ 1000 Ω Short-circuit protectionvoltage output: current limit Compliance with standards and directives Standard conformity StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 EN 60947-5-7:2003 EN61131-9:2013 IEC 60947-5-7:2003 IEC 61131-9:2013 Approvals and certificates IECEx approval Equipment protection level Gc (ec)IECEx TUR 21.0019X Equipment protection level Dc (tc)IECEx TUR 21.0020X ATEX approval Equipment protection level Gc (ec)TÜV 20 ATEX 8525 X Equipment protection level Dc (tc)TÜV 20 ATEX 8526 X UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure Marine approvalDNVGL TAA00001V2 Ambient conditions Ambient temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Connection type5-pin, M12 x 1 connector Degree of protectionIP67 / IP69K Material HousingPBT, stainless steel 1.4571 , brass, nickel-plated Targetmild steel, e. g. 1.0037, SR235JR (formerly St37-2) Mass113 g General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270702 ECLASS 10.0.127270702 ECLASS 9.027270702 ECLASS 8.027270702 ECLASS 5.127270702 ETIM 8.0EC001852 ETIM 7.0EC001852 ETIM 6.0EC001852 ETIM 5.0EC001852

公司评介