PMI14V-F112-2EPE2-IO PEPPERL+FUCHS - Part number: 263758
缺货 - 延期交货
要从制造商订购
USD439.86

不含进口税

必须记录您

PMI14V-F112-2EPE2-IO PEPPERL+FUCHS - Part number: 263758

PEPPERL+FUCHS

Inductive positioning system PMI14V-F112-2EPE2-IO PMI14V-F112-2EPE2-IO Parameterization and diagnosis via IO-Link 3 configurable switching frames Measuring range 0 ... 14 mm Shielded line 2 m Inductive positioning system PMI14V-F112-2EPE2-IO PMI14V-F112-2EPE2-IO Parameterization and diagnosis via IO-Link 3 configurable switching frames Measuring range 0 ... 14 mm Shielded line 2 m

MPNs 263758, PEP263758, PMI14V-F112-2EPE2-IO
税则号 85219000
Weight N/A

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD439.86

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  PMI14V-F112-2EPE2-IO General specifications Installationflush Object distancemax. 2.5 mm Measurement range0 ... 14 mm Nominal ratings Operating voltage10 ... 30 V Reverse polarity protectionreverse polarity protected Linearity error± 0.3 mm Repeat accuracy± 0.05 mm Resolution33 µm Temperature drift± 0.5 mm No-load supply current≤ 20 mA Operating voltage indicatorLED green Functional safety related parameters MTTFd490 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Interface Interface typeIO-Link ModeCOM2 (38.4 kBit/s) Value range0000h ... 7000h Switching output Output type2 Push-pull (4 in 1) outputs , 1 switch output PNP , short-circuit protected , reverse polarity protected , overvoltage protected , programmable Operating current≤ 100 mA / Output Switching hysteresis3-step, adjustable 0.2 m ... 0.8 mm Voltage drop≤ 3 V Short-circuit protectionpulsing Compliance with standards and directives Standard conformity StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 Approvals and certificates UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Mechanical specifications Connection type2 m PUR cable , screened Housing materialdiecast zinc, not laquered or coated Degree of protectionIP67 Material Targetmild steel, e. g. 1.0037, SR235JR (formerly St37-2) Cable Cable diameter4.8 mm Bending radius> 10 x cable diameter NoteThe data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5  mm. Classifications SystemClasscode ECLASS 11.027270702 ECLASS 10.0.127270702 ECLASS 9.027270702 ECLASS 8.027270702 ECLASS 5.127270702 ETIM 8.0EC001852 ETIM 7.0EC001852 ETIM 6.0EC001852 ETIM 5.0EC001852 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  PMI14V-F112-2EPE2-IO General specifications Installationflush Object distancemax. 2.5 mm Measurement range0 ... 14 mm Nominal ratings Operating voltage10 ... 30 V Reverse polarity protectionreverse polarity protected Linearity error± 0.3 mm Repeat accuracy± 0.05 mm Resolution33 µm Temperature drift± 0.5 mm No-load supply current≤ 20 mA Operating voltage indicatorLED green Functional safety related parameters MTTFd490 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Interface Interface typeIO-Link ModeCOM2 (38.4 kBit/s) Value range0000h ... 7000h Switching output Output type2 Push-pull (4 in 1) outputs , 1 switch output PNP , short-circuit protected , reverse polarity protected , overvoltage protected , programmable Operating current≤ 100 mA / Output Switching hysteresis3-step, adjustable 0.2 m ... 0.8 mm Voltage drop≤ 3 V Short-circuit protectionpulsing Compliance with standards and directives Standard conformity StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 Approvals and certificates UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Mechanical specifications Connection type2 m PUR cable , screened Housing materialdiecast zinc, not laquered or coated Degree of protectionIP67 Material Targetmild steel, e. g. 1.0037, SR235JR (formerly St37-2) Cable Cable diameter4.8 mm Bending radius> 10 x cable diameter NoteThe data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5  mm. Classifications SystemClasscode ECLASS 11.027270702 ECLASS 10.0.127270702 ECLASS 9.027270702 ECLASS 8.027270702 ECLASS 5.127270702 ETIM 8.0EC001852 ETIM 7.0EC001852 ETIM 6.0EC001852 ETIM 5.0EC001852 UNSPSC 12.139121550