UBC250-12GM-E5-V1 PEPPERL+FUCHS - Part number: 197204
缺货 - 延期交货
要从制造商订购
USD767.08

不含进口税

必须记录您

UBC250-12GM-E5-V1 PEPPERL+FUCHS - Part number: 197204

PEPPERL+FUCHS

Ultrasonic sensor UBC250-12GM-E5-V1 UBC250-12GM-E5-V1 High chemical resistance through PTFE coated transducer surface Stainless Steel enclosure 1 switch output Temperature compensation Programmable output functions Program input Ultrasonic sensor UBC250-12GM-E5-V1 UBC250-12GM-E5-V1 High chemical resistance through PTFE coated transducer surface Stainless Steel enclosure 1 switch output Temperature compensation Programmable output functions Program input

MPNs 197204, PEP197204, UBC250-12GM-E5-V1
税则号 90318000
Weight N/A

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD767.08

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  UBC250-12GM-E5-V1 General specifications Sensing range30 ... 250 mm Adjustment range50 ... 250 mm Dead band0 ... 30 mm Standard target plate100 mm x 100 mm Transducer frequency310 kHz Response delay50 ms Electrical specifications Operating voltage10 ... 30 V DC , ripple 10 %SS No-load supply current≤ 30 mA Input Input type1 program inputlower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s Output Output type1 switch output PNP Normally open/closed , programmable Rated operating current100 mA , short-circuit/overload protected Default settingSwitch point A1: 50 mm Switch point A2: 250 mm Voltage drop≤ 3 V Repeat accuracy≤ 1 % Switching frequency≤ 8 Hz Range hysteresis1 % of the set operating distance Temperature influence± 1.5 % of full-scale value Compliance with standards and directives Standard conformity StandardsEN IEC 60947-5-2:2020 IEC 60947-5-2:2019 Approvals and certificates EAC conformityTR CU 020/2011 TR CU 037/2016 UL approvalcULus Listed, Class 2 Power Source CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Connection typeConnector plug M12 x 1 , 4-pin Housing diameter12 mm Degree of protectionIP68 / IP69K Material HousingStainless steel 1.4404 / AISI 316L O-ring for cover seal: Viton TransducerPTFE (diaphragm surface) Mass35 g Classifications SystemClasscode ECLASS 11.027272803 ECLASS 10.0.127272803 ECLASS 9.027272803 ECLASS 8.027272803 ECLASS 5.127272803 ETIM 8.0EC001849 ETIM 7.0EC001849 ETIM 6.0EC001849 ETIM 5.0EC001849 UNSPSC 12.141111960 Datasheet excerpt: Technical data of  UBC250-12GM-E5-V1 General specifications Sensing range30 ... 250 mm Adjustment range50 ... 250 mm Dead band0 ... 30 mm Standard target plate100 mm x 100 mm Transducer frequency310 kHz Response delay50 ms Electrical specifications Operating voltage10 ... 30 V DC , ripple 10 %SS No-load supply current≤ 30 mA Input Input type1 program inputlower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s Output Output type1 switch output PNP Normally open/closed , programmable Rated operating current100 mA , short-circuit/overload protected Default settingSwitch point A1: 50 mm Switch point A2: 250 mm Voltage drop≤ 3 V Repeat accuracy≤ 1 % Switching frequency≤ 8 Hz Range hysteresis1 % of the set operating distance Temperature influence± 1.5 % of full-scale value Compliance with standards and directives Standard conformity StandardsEN IEC 60947-5-2:2020 IEC 60947-5-2:2019 Approvals and certificates EAC conformityTR CU 020/2011 TR CU 037/2016 UL approvalcULus Listed, Class 2 Power Source CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Connection typeConnector plug M12 x 1 , 4-pin Housing diameter12 mm Degree of protectionIP68 / IP69K Material HousingStainless steel 1.4404 / AISI 316L O-ring for cover seal: Viton TransducerPTFE (diaphragm surface) Mass35 g Classifications SystemClasscode ECLASS 11.027272803 ECLASS 10.0.127272803 ECLASS 9.027272803 ECLASS 8.027272803 ECLASS 5.127272803 ETIM 8.0EC001849 ETIM 7.0EC001849 ETIM 6.0EC001849 ETIM 5.0EC001849 UNSPSC 12.141111960

公司评介