VDM100-300-SSI/G2 PEPPERL+FUCHS - Part number: 241272
可应要求

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

VDM100-300-SSI/G2 PEPPERL+FUCHS - Part number: 241272

PEPPERL+FUCHS

Distance sensor VDM100-300-SSI/G2 VDM100-300-SSI/G2 Measuring method PRT (Pulse Ranging Technology) Non-contact precision measurement Switchable SSI/RS 422 interface Ultra-fast data acquisition Active dynamic control Modern lightweight design, extremely robust Simple programming with 4 keys and luminous display Distance sensor VDM100-300-SSI/G2 VDM100-300-SSI/G2 Measuring method PRT (Pulse Ranging Technology) Non-contact precision measurement Switchable SSI/RS 422 interface Ultra-fast data acquisition Active dynamic control Modern lightweight design, extremely robust Simple programming with 4 keys and luminous display

MPNs 241272, PEP241272, VDM100-300-SSI/G2
税则号 90318000
Weight 0.7 kg

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

可应要求

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  VDM100-300-SSI/G2 Product Description Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 300 m, SSI interface - switchable to RS-422, M12 plug General specifications Measurement range0.3 ... 300 m Reference targetReflector VDM01 Light sourcelaser diode Laser nominal ratings NoteVISIBLE AND INVISIBLE LASER RADIATION , DO NOT STARE INTO BEAM Laser classMeasuring laser: 1 Alignment laser: 2 Wave lengthMeasuring laser: 905 nm Alignment laser: 660 nm Beam divergenceMeasuring laser: 2 mrad Alignment laser: 1 mrad Pulse lengthMeasuring laser: 4 ns Repetition rateMeasuring laser: 20 kHz Maximum optical power output  Alignment laser: 0.6 mW max. pulse energyMeasuring laser: 12 nJ Measuring methodPulse Ranging Technology (PRT) Max. Motion velocity15 m/s Alignment aidLaser pointer Laser class 2 Life span> 100000 h Diameter of the light spot< 70 cm at 300 m Ambient light limit> 100000 Lux Resolution0.1 mm , adjustable Temperature influence0.03 mm/K Functional safety related parameters MTTFd120 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Function indicator4 LEDs Control elementsControl panel (4 membrane keys) for setting parameters Parameterization indicatorIlluminated display for displaying measured values and parameterization Electrical specifications Operating voltage18 ... 30 V DC No-load supply current250 mA (18 V) ... 150 mA (30 V) Protection classIII (operating voltage 50 V) Time delay before availability< 10 s Interface Interface typeSSI Read out rate4000/s Clock frequency: 100 kHz ... 1 MHz Interface 1 Interface typeRS-422 Read out rate4.8 ... 115.2 kBit/s Input/Output Input/output type2 PNP inputs/outputs, independent configuration, short-circuit protected, reverse polarity protected Input Switching thresholdlow: Ue < 6 V,high: Ue > 16 V Output Switching thresholdlow: Ua < 1 V,high: Ua > Ub - 1 V Switching current200 mA per output Conformity Product standardEN 60947-5-2 Laser safetyIEC 60825-1:2007 Measurement accuracy Measured value output1 ms Average data age3 ms , 6 ms , 12 ms , 25 ms , 50 ms , adjustable Offsetmax. 2 mm (between two devices) Absolute accuracy± 2.5 mm (> 3 m); ± 3.5 mm (0.3 m to 3 m) Repeat accuracy< 0.5 mm Approvals and certificates EAC conformityTR CU 020/2011 UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure FDA approvalIEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 Ambient conditions Ambient temperature-10 ... 50 °C (14 ... 122 °F) Storage temperature-20 ... 70 °C (-4 ... 158 °F) Relative humidity95 % , no moisture condensation Mechanical specifications Housing width140 mm Housing height100 mm Degree of protectionIP65 Connection4-pin, M12x1 connector, standard (supply) ,5-pin, M12x1 connector, B-coded (SSI) ,8-pin, M12x1 connector, service Material HousingABS / PC Optical facePMMA , hard coated Mass700 g Classifications SystemClasscode ECLASS 11.027270801 ECLASS 10.0.127270801 ECLASS 9.027270801 ECLASS 8.027270801 ECLASS 5.127270801 ETIM 8.0EC001825 ETIM 7.0EC001825 ETIM 6.0EC001825 ETIM 5.0EC001825 UNSPSC 12.141111613 Datasheet excerpt: Technical data of  VDM100-300-SSI/G2 Product Description Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 300 m, SSI interface - switchable to RS-422, M12 plug General specifications Measurement range0.3 ... 300 m Reference targetReflector VDM01 Light sourcelaser diode Laser nominal ratings NoteVISIBLE AND INVISIBLE LASER RADIATION , DO NOT STARE INTO BEAM Laser classMeasuring laser: 1 Alignment laser: 2 Wave lengthMeasuring laser: 905 nm Alignment laser: 660 nm Beam divergenceMeasuring laser: 2 mrad Alignment laser: 1 mrad Pulse lengthMeasuring laser: 4 ns Repetition rateMeasuring laser: 20 kHz Maximum optical power output  Alignment laser: 0.6 mW max. pulse energyMeasuring laser: 12 nJ Measuring methodPulse Ranging Technology (PRT) Max. Motion velocity15 m/s Alignment aidLaser pointer Laser class 2 Life span> 100000 h Diameter of the light spot< 70 cm at 300 m Ambient light limit> 100000 Lux Resolution0.1 mm , adjustable Temperature influence0.03 mm/K Functional safety related parameters MTTFd120 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Function indicator4 LEDs Control elementsControl panel (4 membrane keys) for setting parameters Parameterization indicatorIlluminated display for displaying measured values and parameterization Electrical specifications Operating voltage18 ... 30 V DC No-load supply current250 mA (18 V) ... 150 mA (30 V) Protection classIII (operating voltage 50 V) Time delay before availability< 10 s Interface Interface typeSSI Read out rate4000/s Clock frequency: 100 kHz ... 1 MHz Interface 1 Interface typeRS-422 Read out rate4.8 ... 115.2 kBit/s Input/Output Input/output type2 PNP inputs/outputs, independent configuration, short-circuit protected, reverse polarity protected Input Switching thresholdlow: Ue < 6 V,high: Ue > 16 V Output Switching thresholdlow: Ua < 1 V,high: Ua > Ub - 1 V Switching current200 mA per output Conformity Product standardEN 60947-5-2 Laser safetyIEC 60825-1:2007 Measurement accuracy Measured value output1 ms Average data age3 ms , 6 ms , 12 ms , 25 ms , 50 ms , adjustable Offsetmax. 2 mm (between two devices) Absolute accuracy± 2.5 mm (> 3 m); ± 3.5 mm (0.3 m to 3 m) Repeat accuracy< 0.5 mm Approvals and certificates EAC conformityTR CU 020/2011 UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure FDA approvalIEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 Ambient conditions Ambient temperature-10 ... 50 °C (14 ... 122 °F) Storage temperature-20 ... 70 °C (-4 ... 158 °F) Relative humidity95 % , no moisture condensation Mechanical specifications Housing width140 mm Housing height100 mm Degree of protectionIP65 Connection4-pin, M12x1 connector, standard (supply) ,5-pin, M12x1 connector, B-coded (SSI) ,8-pin, M12x1 connector, service Material HousingABS / PC Optical facePMMA , hard coated Mass700 g Classifications SystemClasscode ECLASS 11.027270801 ECLASS 10.0.127270801 ECLASS 9.027270801 ECLASS 8.027270801 ECLASS 5.127270801 ETIM 8.0EC001825 ETIM 7.0EC001825 ETIM 6.0EC001825 ETIM 5.0EC001825 UNSPSC 12.141111613

公司评介