DA6-IU-2K-V PEPPERL+FUCHS - Part number: 247820
缺货 - 延期交货
要从制造商订购
USD663.67

不含进口税

必须记录您

DA6-IU-2K-V PEPPERL+FUCHS - Part number: 247820

PEPPERL+FUCHS

Process control and indication equipment DA6-IU-2K-V DA6-IU-2K-V 2 adjustable trip values 2 relay outputs Operation via keypad Characteristic programmable via 12 interpolation points Resetting the outputs, automatic, manual or with external signal Connection via plug-in screw terminals Auxiliary power output for sensors Degree of protection IP65 in accordance with DIN EN 60529 (front only) System hum suppression Process control and indication equipment DA6-IU-2K-V DA6-IU-2K-V 2 adjustable trip values 2 relay outputs Operation via keypad Characteristic programmable via 12 interpolation points Resetting the outputs, automatic, manual or with external signal Connection via plug-in screw terminals Auxiliary power output for sensors Degree of protection IP65 in accordance with DIN EN 60529 (front only) System hum suppression

MPNs 247820, PEP247820, DA6-IU-2K-V
税则号 90262000
Weight 0.18 kg

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD663.67

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  DA6-IU-2K-V Product Description Process control and indication equipment General specifications Pre-selection2-fold Data storage> 10 years, EEPROM Programmingkeypad-driven menu Indicators/operating means Type14-segment LED display, red Number of digits6 Display valuedigit height 14 mm Key interlockwith "high"-level at terminal "KEY" Display interval-199999 ... 999999 with suppression of leading zeros Decimal pointfreely adjustable Resolution15 Bit Scale factorvia characteristic curve with up to 12 value pairs Resetmanually or external Electrical specifications FusingT 0.1 A Operating voltage90 ... 260 V AC Power consumption9 VA Input Impedance> 1 MΩ for voltage measurement < 50 Ω for current measurement Analog voltage input0 ... 10 V / 2 ... 10 V DC,-10 ... 10 V DC Analog current input0 ... 20 mA / 4 ... 20 mA Output Relaychangeover contact Switching voltagemax. 250 V AC / 125 V DC min. 5 V AC / 5 V DC Switching currentmax. 5 A AC / 5 A DC min. 10 mA DC Switching powermax. 1250 VA / 150 W Sensor supply24 V DC ± 15 % , 30 mA 15 V DC ± 1 %, 25 mA Compliance with standards and directives Directive conformity EMC Directive 2004/108/ECEN 61000-6-2:2006 (With shielded signal and control lines) DIN EN 55011:2009, Class B Standard conformity Galvanic isolationEN 61010-1:2010 Degree of protectionEN 60529:1991 + A1:2000 Shock and impact resistanceEN 60068-2-27:2009 EN 60068-2-29:1995 Vibration resistanceEN 60068-2-6:2008 Ambient conditions Ambient temperature-10 ... 50 °C (14 ... 122 °F) Storage temperature-20 ... 70 °C (-4 ... 158 °F) Relative humidity≤ 80 % (noncondensing) Mechanical specifications Degree of protectionIP65 (front) Connection8-pin and 9-pin connectors with screw terminals Mass180 g Dimensions96 mm x 48 mm x 102 mm Mountingmounting frame with latch fastener Classifications SystemClasscode ECLASS 11.027210301 ECLASS 10.0.127210301 ECLASS 9.027210301 ECLASS 8.027210301 ECLASS 5.127210301 ETIM 8.0EC002300 ETIM 7.0EC002300 ETIM 6.0EC002300 ETIM 5.0EC000677 UNSPSC 12.143211906 Datasheet excerpt: Technical data of  DA6-IU-2K-V Product Description Process control and indication equipment General specifications Pre-selection2-fold Data storage> 10 years, EEPROM Programmingkeypad-driven menu Indicators/operating means Type14-segment LED display, red Number of digits6 Display valuedigit height 14 mm Key interlockwith "high"-level at terminal "KEY" Display interval-199999 ... 999999 with suppression of leading zeros Decimal pointfreely adjustable Resolution15 Bit Scale factorvia characteristic curve with up to 12 value pairs Resetmanually or external Electrical specifications FusingT 0.1 A Operating voltage90 ... 260 V AC Power consumption9 VA Input Impedance> 1 MΩ for voltage measurement < 50 Ω for current measurement Analog voltage input0 ... 10 V / 2 ... 10 V DC,-10 ... 10 V DC Analog current input0 ... 20 mA / 4 ... 20 mA Output Relaychangeover contact Switching voltagemax. 250 V AC / 125 V DC min. 5 V AC / 5 V DC Switching currentmax. 5 A AC / 5 A DC min. 10 mA DC Switching powermax. 1250 VA / 150 W Sensor supply24 V DC ± 15 % , 30 mA 15 V DC ± 1 %, 25 mA Compliance with standards and directives Directive conformity EMC Directive 2004/108/ECEN 61000-6-2:2006 (With shielded signal and control lines) DIN EN 55011:2009, Class B Standard conformity Galvanic isolationEN 61010-1:2010 Degree of protectionEN 60529:1991 + A1:2000 Shock and impact resistanceEN 60068-2-27:2009 EN 60068-2-29:1995 Vibration resistanceEN 60068-2-6:2008 Ambient conditions Ambient temperature-10 ... 50 °C (14 ... 122 °F) Storage temperature-20 ... 70 °C (-4 ... 158 °F) Relative humidity≤ 80 % (noncondensing) Mechanical specifications Degree of protectionIP65 (front) Connection8-pin and 9-pin connectors with screw terminals Mass180 g Dimensions96 mm x 48 mm x 102 mm Mountingmounting frame with latch fastener Classifications SystemClasscode ECLASS 11.027210301 ECLASS 10.0.127210301 ECLASS 9.027210301 ECLASS 8.027210301 ECLASS 5.127210301 ETIM 8.0EC002300 ETIM 7.0EC002300 ETIM 6.0EC002300 ETIM 5.0EC000677 UNSPSC 12.143211906

公司评介