KC-LCDC-48-2T-230VAC PEPPERL+FUCHS - Part number: 214738
缺货 - 延期交货
要从制造商订购
USD425.17

不含进口税

必须记录您

KC-LCDC-48-2T-230VAC PEPPERL+FUCHS - Part number: 214738

PEPPERL+FUCHS

Timer, Counter, Tachometer KC-LCDC-48-2T-230VAC KC-LCDC-48-2T-230VAC Counter/Timer/Tachometer Adding/subtracting via 2 separate inputs Batch controller with 2 pre-selections 2 potential-free optocoupler outputs Easy-to-read 2-line LCD display, color, with icons for the displayed preselection and the status of both outputs Multicolor display Display range and preselection range from -999999 up to 999999Overflow will be evaluated correctly up to 1 decade PNP and NPN sensors can be connected Degree of protection IP65 (front only) Timer, Counter, Tachometer KC-LCDC-48-2T-230VAC KC-LCDC-48-2T-230VAC Counter/Timer/Tachometer Adding/subtracting via 2 separate inputs Batch controller with 2 pre-selections 2 potential-free optocoupler outputs Easy-to-read 2-line LCD display, color, with icons for the displayed preselection and the status of both outputs Multicolor display Display range and preselection range from -999999 up to 999999Overflow will be evaluated correctly up to 1 decade PNP and NPN sensors can be connected Degree of protection IP65 (front only)

MPNs 214738, PEP214738, KC-LCDC-48-2T-230VAC
税则号 90262000
Weight 0.13 kg

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD425.17

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  KC-LCDC-48-2T-230VAC Product Description LCD batch controller with 2 optocoupler outputs and 90 ... 260 VAC supply voltage General specifications Pre-selection2-fold Data storage> 10 years, EEPROM Programmingkeypad-driven menu Functional safety related parameters MTTFd410 a Mission Time (TM)10 a Diagnostic Coverage (DC)0 % Indicators/operating means Type2-line, 2 x 6-digit LC display with leading sign Multicolor, backlit Display valuedigit height 9 mm Pre-selectiondigit height 7 mm Key interlockvia "high" potential at "LOCK" input Decimal point0 to max 5 fractional digits Scale factor0.0001 ... 99.9999 Resetmanually or external Electrical specifications Fusing90 … 260 V AC: T 0.1 A Operating voltage90 ... 260 V AC Power consumptionmax. 8 VA Input ConnectionCounter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI Signal voltage High12 ... 30 V DC Low0 ... 4 V DC Counting frequency30 Hz / 55 kHz Minimum pulse durationControl/reset inputs: 10 ms / 1 ms Impedance5 kOhm Count modes Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad), Cumulative counting (up.up),up/down counting x 2 (quad 2),up/down counting x 4 (quad 4),additional functions for counter input A and counter input B: A/B, (A-B)/A x 100%  Frequency counterfunctions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 % TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto) Output Sensor supply20.4 ... 27.6 V DC, max. 80 mA Response time1 ms OptocouplerSchaltleistung 30 V DC / 10 mA Signal voltageUCESAT with IC = 10 mA: max. 2 V UCESAT with IC = 5 mA: max. 0.4 V Compliance with standards and directives Directive conformity Low Voltage Directive 2006/95/ECEN 61010-1:2001; protection class: 2 EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999 Standard conformity Emitted interferenceDIN EN 55011:2009, Class B Mech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction Shock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction Ambient conditions Ambient temperature-20 ... 65 °C (-4 ... 149 °F) Storage temperature-25 ... 75 °C (-13 ... 167 °F) Relative humidity≤ 93 % at 40 °C(noncondensing) Altitude0 ... 2000 m Pollution degree2 Mechanical specifications Degree of protectionIP65 (front) Mass134 g Dimensions48 mm x 48 mm x 109.8 mm Classifications SystemClasscode ECLASS 11.027210301 ECLASS 10.0.127210301 ECLASS 9.027210301 ECLASS 8.027210301 ECLASS 5.127210301 ETIM 8.0EC002300 ETIM 7.0EC002300 ETIM 6.0EC002300 ETIM 5.0EC000677 UNSPSC 12.141111902 Datasheet excerpt: Technical data of  KC-LCDC-48-2T-230VAC Product Description LCD batch controller with 2 optocoupler outputs and 90 ... 260 VAC supply voltage General specifications Pre-selection2-fold Data storage> 10 years, EEPROM Programmingkeypad-driven menu Functional safety related parameters MTTFd410 a Mission Time (TM)10 a Diagnostic Coverage (DC)0 % Indicators/operating means Type2-line, 2 x 6-digit LC display with leading sign Multicolor, backlit Display valuedigit height 9 mm Pre-selectiondigit height 7 mm Key interlockvia "high" potential at "LOCK" input Decimal point0 to max 5 fractional digits Scale factor0.0001 ... 99.9999 Resetmanually or external Electrical specifications Fusing90 … 260 V AC: T 0.1 A Operating voltage90 ... 260 V AC Power consumptionmax. 8 VA Input ConnectionCounter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI Signal voltage High12 ... 30 V DC Low0 ... 4 V DC Counting frequency30 Hz / 55 kHz Minimum pulse durationControl/reset inputs: 10 ms / 1 ms Impedance5 kOhm Count modes Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad), Cumulative counting (up.up),up/down counting x 2 (quad 2),up/down counting x 4 (quad 4),additional functions for counter input A and counter input B: A/B, (A-B)/A x 100%  Frequency counterfunctions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 % TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto) Output Sensor supply20.4 ... 27.6 V DC, max. 80 mA Response time1 ms OptocouplerSchaltleistung 30 V DC / 10 mA Signal voltageUCESAT with IC = 10 mA: max. 2 V UCESAT with IC = 5 mA: max. 0.4 V Compliance with standards and directives Directive conformity Low Voltage Directive 2006/95/ECEN 61010-1:2001; protection class: 2 EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999 Standard conformity Emitted interferenceDIN EN 55011:2009, Class B Mech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction Shock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction Ambient conditions Ambient temperature-20 ... 65 °C (-4 ... 149 °F) Storage temperature-25 ... 75 °C (-13 ... 167 °F) Relative humidity≤ 93 % at 40 °C(noncondensing) Altitude0 ... 2000 m Pollution degree2 Mechanical specifications Degree of protectionIP65 (front) Mass134 g Dimensions48 mm x 48 mm x 109.8 mm Classifications SystemClasscode ECLASS 11.027210301 ECLASS 10.0.127210301 ECLASS 9.027210301 ECLASS 8.027210301 ECLASS 5.127210301 ETIM 8.0EC002300 ETIM 7.0EC002300 ETIM 6.0EC002300 ETIM 5.0EC000677 UNSPSC 12.141111902