Rotation Speed Monitor KFU8-DW-1.D KFU8-DW-1.D Speed monitoring up to 40 kHz 1 pre-select value with relay output and LED indicator 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable Start-up delay Menu driven operation via 4 front keys Period measurement Output signal can be inverted Display devices can be set between 0.1 ... 2.5 sec. Rotation Speed Monitor KFU8-DW-1.D KFU8-DW-1.D Speed monitoring up to 40 kHz 1 pre-select value with relay output and LED indicator 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable Start-up delay Menu driven operation via 4 front keys Period measurement Output signal can be inverted Display devices can be set between 0.1 ... 2.5 sec.

MPNs 190149, PEP190149, KFU8-DW-1.D
Weight N/A

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD619.71

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  KFU8-DW-1.D Product Description Rotation Speed Monitor Functional safety related parameters MTTFd100 a Supply Rated voltage200 ... 230 V AC ; 100 … 130 V AC; 50/60 Hz 20 VDC ... 30 VDC Fusingexternal fusing 4 A Power consumptionAC: < 5 VADC: < 5 W Input 1 Connectionterminals 8-, 9+ Connectable sensor typesNAMUR sensors according to DIN EN 60947-5-6 Open loop voltage8.2 V DC Short-circuit current6.5 mA Switching point1.2 ... 2.1 mA Switching hysteresis 0.2 mA Input frequency0.002 ... 10000 Hz, pulse length/duration: ≥ 20µs Impedance1.2 kΩ Input 2 Switching pointhigh: 16 ... 30 V DC; max.10 mA due to integrated constant current sink; Ri ≅ 3 kΩlow: 0 ... 6 V DC Input frequency0.002 ... 40000 Hz, pulse length/duration: ≥ 12µs Connectionterminals 7+, 13- sensor supplyterminals 14, 15 NPN/PNP input (galvanically isolated) Connectable sensor typesTwo, three, or four-wire proximity switch, incremental rotary encoder, or externally generated pulses 16 ... 30 V Sensor supply19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit protected Input 3 Start-up overrideTriggering by external signal 16 ... 30 V or Place jumper between terminals 2/3 or by switching on supply voltage (terminal 2 and terminal 3 permanently bridged) Jumpering time0.1 ... 999.9 s (External trigger signal) Output Relay1 changeover contact NO, NC, COM Sensor supply24 V DC ± 10 %, 30 mA , short-circuit protected Contact loading250 V AC/2 A/ cos φ ≥ 0.740 V DC/2 A Delay≤ 20 ms (incl. calculation time) Mechanical life≥ 30.000.000 switching cycles Transfer characteristics Changing interval5 ms (Internal processing time) Time delay before availability≤ 400 ms Measuring error0 ... 40000 Hz: ≤ ±0,10% Display: ±1 digit Timer functionON-delay, OFF-delay, one shot, pulse extension Time0 ... 999.9 s ; mode of operation reversible Standard conformity Electromagnetic compatibilityacc. to EN 50081-2 / EN 50082-2 Ambient conditions Ambient temperature-25 ... 40 °C (-13 ... 104 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Relative humiditymax. 80 %, not condensing Altitude0 ... 2000 m Operating conditionsThe device has only to be used in an indoor area. Mechanical specifications Connection assemblyCaution: Please be aware that the device may only be connected to a switchable power supply. The switch or circuit breaker must be easy to reach and identified as the separator for the device. Degree of protectionIP20 Connectioncoded, removable terminals , max. core cross section 0.34 ... 2.5 mm2 Construction typemodular terminal housing in Makrolon, System KF For use in the switch cabinet/switch cabinet module Mountingsnap-on to 35 mm standard rail or screw fixing Classifications SystemClasscode ECLASS 11.027210904 ECLASS 10.0.127210904 ECLASS 9.027210904 ECLASS 8.027210904 ECLASS 5.127210904 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007 Datasheet excerpt: Technical data of  KFU8-DW-1.D Product Description Rotation Speed Monitor Functional safety related parameters MTTFd100 a Supply Rated voltage200 ... 230 V AC ; 100 … 130 V AC; 50/60 Hz 20 VDC ... 30 VDC Fusingexternal fusing 4 A Power consumptionAC: < 5 VADC: < 5 W Input 1 Connectionterminals 8-, 9+ Connectable sensor typesNAMUR sensors according to DIN EN 60947-5-6 Open loop voltage8.2 V DC Short-circuit current6.5 mA Switching point1.2 ... 2.1 mA Switching hysteresis 0.2 mA Input frequency0.002 ... 10000 Hz, pulse length/duration: ≥ 20µs Impedance1.2 kΩ Input 2 Switching pointhigh: 16 ... 30 V DC; max.10 mA due to integrated constant current sink; Ri ≅ 3 kΩlow: 0 ... 6 V DC Input frequency0.002 ... 40000 Hz, pulse length/duration: ≥ 12µs Connectionterminals 7+, 13- sensor supplyterminals 14, 15 NPN/PNP input (galvanically isolated) Connectable sensor typesTwo, three, or four-wire proximity switch, incremental rotary encoder, or externally generated pulses 16 ... 30 V Sensor supply19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit protected Input 3 Start-up overrideTriggering by external signal 16 ... 30 V or Place jumper between terminals 2/3 or by switching on supply voltage (terminal 2 and terminal 3 permanently bridged) Jumpering time0.1 ... 999.9 s (External trigger signal) Output Relay1 changeover contact NO, NC, COM Sensor supply24 V DC ± 10 %, 30 mA , short-circuit protected Contact loading250 V AC/2 A/ cos φ ≥ 0.740 V DC/2 A Delay≤ 20 ms (incl. calculation time) Mechanical life≥ 30.000.000 switching cycles Transfer characteristics Changing interval5 ms (Internal processing time) Time delay before availability≤ 400 ms Measuring error0 ... 40000 Hz: ≤ ±0,10% Display: ±1 digit Timer functionON-delay, OFF-delay, one shot, pulse extension Time0 ... 999.9 s ; mode of operation reversible Standard conformity Electromagnetic compatibilityacc. to EN 50081-2 / EN 50082-2 Ambient conditions Ambient temperature-25 ... 40 °C (-13 ... 104 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Relative humiditymax. 80 %, not condensing Altitude0 ... 2000 m Operating conditionsThe device has only to be used in an indoor area. Mechanical specifications Connection assemblyCaution: Please be aware that the device may only be connected to a switchable power supply. The switch or circuit breaker must be easy to reach and identified as the separator for the device. Degree of protectionIP20 Connectioncoded, removable terminals , max. core cross section 0.34 ... 2.5 mm2 Construction typemodular terminal housing in Makrolon, System KF For use in the switch cabinet/switch cabinet module Mountingsnap-on to 35 mm standard rail or screw fixing Classifications SystemClasscode ECLASS 11.027210904 ECLASS 10.0.127210904 ECLASS 9.027210904 ECLASS 8.027210904 ECLASS 5.127210904 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007

公司评介