KFU8-UFT-2.D.FA PEPPERL+FUCHS - Part number: 192334
缺货 - 延期交货
要从制造商订购
USD928.21

不含进口税

必须记录您

KFU8-UFT-2.D.FA PEPPERL+FUCHS - Part number: 192334

PEPPERL+FUCHS

Frequency Converter with Direction and Synchronization Monitor KFU8-UFT-2.D.FA KFU8-UFT-2.D.FA 2-channel signal conditioner Universal usage at different power supplies Dry contact or NAMUR inputs Input frequency 1 mHz ... 1 kHz Current output 0/4 mA ... 20 mA Relay contact and transistor output Start-up override Configurable by PACTware or keypad Line fault detection (LFD) Frequency Converter with Direction and Synchronization Monitor KFU8-UFT-2.D.FA KFU8-UFT-2.D.FA 2-channel signal conditioner Universal usage at different power supplies Dry contact or NAMUR inputs Input frequency 1 mHz ... 1 kHz Current output 0/4 mA ... 20 mA Relay contact and transistor output Start-up override Configurable by PACTware or keypad Line fault detection (LFD)

MPNs 192334, PEP192334, KFU8-UFT-2.D.FA
税则号 90318000
Weight 0.3 kg

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD928.21

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  KFU8-UFT-2.D.FA General specifications Signal typeDigital Input Supply Connectionterminals 23, 24 Rated voltage20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz Rated current130 mA Power dissipation2.2 W / 3.5 VA Power consumption2.5 W / 4 VA Interface Programming interfaceprogramming socket Input Connection sidefield side Connectioninput I: terminals 1+, 3-input II: terminals 4+, 6- input III: terminals 13+, 14- (control input 1) input IV: terminals 15+, 14- (control input 2) Input I, II2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact Open circuit voltage/short-circuit current8.2 V / 10 mA Switching point/switching hysteresislogic 1: > 2.5 mA ; logic 0: < 1.9 mA Pulse durationmin. 250 µs , overlap on direction of rotation signal: ≥ 125 µs Input frequencyrotation direction monitoring 0.001 ... 1000 Hz slip monitoring 10 ... 1000 Hz Line fault detectionbreakage I ≤ 0.15 mA; short-circuit I > 4 mA Input III, IV Active/PassiveI > 4 mA (for min. 100 ms) / I < 1.5 mA Open circuit voltage/short-circuit current18 V / 5 mA Output Connection sidecontrol side Connectionoutput I: terminals 10, 11, 12 output II: terminals 16, 17, 18 output III: terminals 19+, 20- output IV: terminals 21+, 20- output V: terminals 7-, 8+ Output I, IIsignal, relay Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A Mechanical life5 x 107 switching cycles Energized/De-energized delay20 ms / 20 ms Output III and IVsignal , electronic output, passive Contact loading40 V DC Signal level1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: blocked output (off-state current ≤ 10 µA) Output Vanalog Current range0 ... 20 mA or 4 ... 20 mA Open loop voltagemax. 24 V DC Loadmax. 650 Ω Fault signaldownscale I ≤ 3.6 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43) Programming interface Connectionprogramming socket InterfaceRS 232 Transfer characteristics Input I and II Measurement range0.001 ... 1000 Hz Resolutionslip monitoring: 1% frequency measurement: 0,1% of measured value; but >0.001Hz Accuracyslip monitoring: 1% frequency measurement: 0.5% of measured value; but >0.001Hz Measuring timefrequency measurement: < 100 ms Influence of ambient temperature0.003 %/K (30 ppm) Output I, II Response delay≤ 200 ms Output V Resolution< 10 µA Accuracy< 30 µA Influence of ambient temperature0.005 %/K (50 ppm) Galvanic isolation Input I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Input III, IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Mutual output I, II, IIIreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Mutual output I, II, IV reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III, IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III, IV/input III, IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Output III, IV/Vbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Output V/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/output III, IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Indicators/settings Display elementsLEDs , display Control elementsControl panel Configurationvia operating buttons via PACTware Labelingspace for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61326-1:2006 Low voltage Directive 2014/35/EUEN 61010-1:2010 Conformity Electromagnetic compatibilityNE 21:2006 Degree of protectionIEC 60529:2001 InputEN 60947-5-6:2000 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Mechanical specifications Degree of protectionIP20 Connectionscrew terminals Mass300 g Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C2 Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001 General information Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. Classifications SystemClasscode ECLASS 11.027210128 ECLASS 10.0.127210128 ECLASS 9.027210128 ECLASS 8.027210190 ECLASS 5.127210121 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007 Datasheet excerpt: Technical data of  KFU8-UFT-2.D.FA General specifications Signal typeDigital Input Supply Connectionterminals 23, 24 Rated voltage20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz Rated current130 mA Power dissipation2.2 W / 3.5 VA Power consumption2.5 W / 4 VA Interface Programming interfaceprogramming socket Input Connection sidefield side Connectioninput I: terminals 1+, 3-input II: terminals 4+, 6- input III: terminals 13+, 14- (control input 1) input IV: terminals 15+, 14- (control input 2) Input I, II2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact Open circuit voltage/short-circuit current8.2 V / 10 mA Switching point/switching hysteresislogic 1: > 2.5 mA ; logic 0: < 1.9 mA Pulse durationmin. 250 µs , overlap on direction of rotation signal: ≥ 125 µs Input frequencyrotation direction monitoring 0.001 ... 1000 Hz slip monitoring 10 ... 1000 Hz Line fault detectionbreakage I ≤ 0.15 mA; short-circuit I > 4 mA Input III, IV Active/PassiveI > 4 mA (for min. 100 ms) / I < 1.5 mA Open circuit voltage/short-circuit current18 V / 5 mA Output Connection sidecontrol side Connectionoutput I: terminals 10, 11, 12 output II: terminals 16, 17, 18 output III: terminals 19+, 20- output IV: terminals 21+, 20- output V: terminals 7-, 8+ Output I, IIsignal, relay Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A Mechanical life5 x 107 switching cycles Energized/De-energized delay20 ms / 20 ms Output III and IVsignal , electronic output, passive Contact loading40 V DC Signal level1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: blocked output (off-state current ≤ 10 µA) Output Vanalog Current range0 ... 20 mA or 4 ... 20 mA Open loop voltagemax. 24 V DC Loadmax. 650 Ω Fault signaldownscale I ≤ 3.6 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43) Programming interface Connectionprogramming socket InterfaceRS 232 Transfer characteristics Input I and II Measurement range0.001 ... 1000 Hz Resolutionslip monitoring: 1% frequency measurement: 0,1% of measured value; but >0.001Hz Accuracyslip monitoring: 1% frequency measurement: 0.5% of measured value; but >0.001Hz Measuring timefrequency measurement: < 100 ms Influence of ambient temperature0.003 %/K (30 ppm) Output I, II Response delay≤ 200 ms Output V Resolution< 10 µA Accuracy< 30 µA Influence of ambient temperature0.005 %/K (50 ppm) Galvanic isolation Input I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Input III, IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Mutual output I, II, IIIreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Mutual output I, II, IV reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III, IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III, IV/input III, IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Output III, IV/Vbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Output V/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/output III, IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Indicators/settings Display elementsLEDs , display Control elementsControl panel Configurationvia operating buttons via PACTware Labelingspace for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61326-1:2006 Low voltage Directive 2014/35/EUEN 61010-1:2010 Conformity Electromagnetic compatibilityNE 21:2006 Degree of protectionIEC 60529:2001 InputEN 60947-5-6:2000 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Mechanical specifications Degree of protectionIP20 Connectionscrew terminals Mass300 g Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C2 Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001 General information Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. Classifications SystemClasscode ECLASS 11.027210128 ECLASS 10.0.127210128 ECLASS 9.027210128 ECLASS 8.027210190 ECLASS 5.127210121 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007

公司评介