Multi i/o box Riello UPS - Part number: RIEYSKCIO1B
Out of Stock - Backorder
To order from manufacturer
USD480.94

Import Taxes Excluded

You must be logged

Multi i/o box Riello UPS - Part number: RIEYSKCIO1B

Riello UPS

Multi I/O interface in box version for UPS integration with control systems, configurable relay inputs/outputs and Modbus/Jbus communication over RS485. It enables multiple serial links, multi-polling and monitoring via RS232 according to the installed configuration. Riello compatibility: Multi I/O and Riello UPS systems prepared for I/O interfaces. Multi I/O interface in box version for UPS integration with control systems, configurable relay inputs/outputs and Modbus/Jbus communication over RS485. It enables multiple serial links, multi-polling and monitoring via RS232 according to the installed configuration. Riello compatibility: Multi I/O and Riello UPS systems prepared for I/O interfaces.

MPNs YSKCIO1B, RIEYSKCIO1B
EAN 8023251009761
HS Code 85072000
Weight 1.5 kg
Volumetric weight 2.68 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

USD480.94

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are an Authorized Dealer of Riello UPS
Free express shipping to United States
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Request your tailored technical service

Rely on our expert technical team for a range of personalized services: repair, programming, maintenance, and much more.

Product information

Description

<div class="row"> <div class="col-xs-12"> <h3>Multi I/O interface box version</h3> <p>Communication interface designed to integrate the UPS with control and monitoring systems through configurable input and output signals. Its main function is to transform UPS events, statuses and alarms into contacts or data that can be used by supervisors, PLCs and BMS systems. The card supports multiple serial connections and allows UPS polling by more than one device, a useful feature in installations with firewalls, separate networks or multiple supervision systems. Communication with the UPS is via RS232, while dialogue on RS485 lines can use the Modbus/Jbus protocol.</p> <h4>Technical features</h4> <ul> <li>Configurable relay inputs and outputs for control and monitoring.</li> <li>Communication with UPS via RS232.</li> <li>Modbus/Jbus protocol on RS485 line.</li> <li>Possibility to connect two devices to a single UPS communication port.</li> <li>Indicated format: box version; mechanical details not reported.</li> </ul> <h4>Integration process</h4> <p>Integration requires contact wiring, serial communication setup and event testing. It is recommended to document configured inputs, outputs and logic for maintenance and future troubleshooting.</p> <h4>Configuration software</h4> <p>Configuration depends on the interface settings and on the supervision software connected to the serial or Modbus/Jbus line. Event mapping should follow the technical manual. During commissioning, technicians should also record wiring, protection coordination, alarm mapping and final operating settings so that future maintenance can reproduce the same safe operating conditions. This approach improves traceability in professional installations and supports correct interaction between the accessory, the UPS and the protected load.</p> <h4>Riello compatibility</h4> <p>The Riello compatibility or reference series is: Multi I/O and Riello UPS systems prepared for I/O interfaces.</p> </div> </div> <div class="row"> <div class="col-xs-12"> <h3>Multi I/O interface box version</h3> <p>Communication interface designed to integrate the UPS with control and monitoring systems through configurable input and output signals. Its main function is to transform UPS events, statuses and alarms into contacts or data that can be used by supervisors, PLCs and BMS systems. The card supports multiple serial connections and allows UPS polling by more than one device, a useful feature in installations with firewalls, separate networks or multiple supervision systems. Communication with the UPS is via RS232, while dialogue on RS485 lines can use the Modbus/Jbus protocol.</p> <h4>Technical features</h4> <ul> <li>Configurable relay inputs and outputs for control and monitoring.</li> <li>Communication with UPS via RS232.</li> <li>Modbus/Jbus protocol on RS485 line.</li> <li>Possibility to connect two devices to a single UPS communication port.</li> <li>Indicated format: box version; mechanical details not reported.</li> </ul> <h4>Integration process</h4> <p>Integration requires contact wiring, serial communication setup and event testing. It is recommended to document configured inputs, outputs and logic for maintenance and future troubleshooting.</p> <h4>Configuration software</h4> <p>Configuration depends on the interface settings and on the supervision software connected to the serial or Modbus/Jbus line. Event mapping should follow the technical manual. During commissioning, technicians should also record wiring, protection coordination, alarm mapping and final operating settings so that future maintenance can reproduce the same safe operating conditions. This approach improves traceability in professional installations and supports correct interaction between the accessory, the UPS and the protected load.</p> <h4>Riello compatibility</h4> <p>The Riello compatibility or reference series is: Multi I/O and Riello UPS systems prepared for I/O interfaces.</p> </div> </div>

Technical specifications

Type of accessory/spare part
Other

Our Company Reviews