XCSE3240W024VAA - Cabur - Three-phase power supply input 400-500Vac / output 24Vdc 10A
Available on request

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

XCSE3240W024VAA - Cabur - Three-phase power supply input 400-500Vac / output 24Vdc 10A

Cabur

3-phase DIN-rail switching power supply from the new CSE Easy Power Line. Input 340–550 Vac 47–63 Hz or 480–780 Vdc, output 24 Vdc adjustable 24–28 Vdc at 10 A. 120 mVpp ripple, hold-up 20–40 ms, 90.5–92% efficiency, DC OK LED, dry alarm contact, and reliable overload and short-circuit peak protection. 3-phase DIN-rail switching power supply from the new CSE Easy Power Line. Input 340–550 Vac 47–63 Hz or 480–780 Vdc, output 24 Vdc adjustable 24–28 Vdc at 10 A. 120 mVpp ripple, hold-up 20–40 ms, 90.5–92% efficiency, DC OK LED, dry alarm contact, and reliable overload and short-circuit peak protection.

MPNs XCSE3240W024VAA, CBRXCSE3240W024VAA
EAN 8017963244336
HS Code 85044083
Weight 0.97 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Available on request

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

<div class="container-fluid"> <h3>CSE Easy Power Line 3-phase DIN-rail power supply for 24 Vdc control and auxiliary circuits</h3> <p>The CSE Easy Power Line is the new CSE product family developed for dependable DC distribution in automation panels and standard industrial machines. This 3-phase DIN-rail switching power supply supports stable 24 Vdc delivery with wide input capability, clear monitoring, and protection technologies designed for industrial control cabinet operation.</p> <h4>3-phase input for 400 Vac and 500 Vac networks, plus DC support</h4> <p>The unit is rated for 3x 400–500 Vac and operates over 340–550 Vac at 47–63 Hz. It also accepts 480–780 Vdc, helping standardize designs where AC or DC bus availability varies. Input current consumption is specified at 1.5 A on 400 Vac and 1.4 A on 500 Vac, with 50 A inrush peak current at 400 Vac.</p> <h4>Adjustable 24 Vdc output for panel loads</h4> <ul> <li>Regulated output 24 Vdc with adjustment range 24–28 Vdc</li> <li>Continuous current 10.0 A for PLC I/O, sensors, relays, actuators, and auxiliary DC circuits</li> <li>Ripple at nominal ratings 120 mVpp</li> <li>Hold-up time 20 ms at 400 Vac and 40 ms at 500 Vac</li> </ul> <h4>Diagnostics, protection, and cabinet suitability</h4> <p>DC OK indication and a dry alarm contact (max 1 A) support quick status checks and simple remote signaling. Protection behavior includes overload limiting and short-circuit peak current capability, supporting fault tolerance in control systems. With efficiency 90.5% at 400 Vac and 92% at 500 Vac, IP20 protection degree, and high isolation up to 4.7 kVac input/output, this CSE Easy Power Line unit is built for industrial panels. It operates from -30°C to +70°C with derating above 60°C, and redundant parallel concepts can be implemented using an external ORing diode.</p> </div> :contentReference[oaicite:19]{index=19} <div class="container-fluid"> <h3>CSE Easy Power Line 3-phase DIN-rail power supply for 24 Vdc control and auxiliary circuits</h3> <p>The CSE Easy Power Line is the new CSE product family developed for dependable DC distribution in automation panels and standard industrial machines. This 3-phase DIN-rail switching power supply supports stable 24 Vdc delivery with wide input capability, clear monitoring, and protection technologies designed for industrial control cabinet operation.</p> <h4>3-phase input for 400 Vac and 500 Vac networks, plus DC support</h4> <p>The unit is rated for 3x 400–500 Vac and operates over 340–550 Vac at 47–63 Hz. It also accepts 480–780 Vdc, helping standardize designs where AC or DC bus availability varies. Input current consumption is specified at 1.5 A on 400 Vac and 1.4 A on 500 Vac, with 50 A inrush peak current at 400 Vac.</p> <h4>Adjustable 24 Vdc output for panel loads</h4> <ul> <li>Regulated output 24 Vdc with adjustment range 24–28 Vdc</li> <li>Continuous current 10.0 A for PLC I/O, sensors, relays, actuators, and auxiliary DC circuits</li> <li>Ripple at nominal ratings 120 mVpp</li> <li>Hold-up time 20 ms at 400 Vac and 40 ms at 500 Vac</li> </ul> <h4>Diagnostics, protection, and cabinet suitability</h4> <p>DC OK indication and a dry alarm contact (max 1 A) support quick status checks and simple remote signaling. Protection behavior includes overload limiting and short-circuit peak current capability, supporting fault tolerance in control systems. With efficiency 90.5% at 400 Vac and 92% at 500 Vac, IP20 protection degree, and high isolation up to 4.7 kVac input/output, this CSE Easy Power Line unit is built for industrial panels. It operates from -30°C to +70°C with derating above 60°C, and redundant parallel concepts can be implemented using an external ORing diode.</p> </div> :contentReference[oaicite:19]{index=19}