Frequency Converter with Trip Values KFU8-UFC-1.D.FA KFU8-UFC-1.D.FA 1-channel signal conditioner Universal usage at different power supplies Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts Input frequency 1 mHz ... 10 kHz Current output 0/4 mA ... 20 mA Relay contact and transistor output Start-up override Line fault detection (LFD) Up to SIL 2 acc. to IEC 61508/IEC 61511 Frequency Converter with Trip Values KFU8-UFC-1.D.FA KFU8-UFC-1.D.FA 1-channel signal conditioner Universal usage at different power supplies Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts Input frequency 1 mHz ... 10 kHz Current output 0/4 mA ... 20 mA Relay contact and transistor output Start-up override Line fault detection (LFD) Up to SIL 2 acc. to IEC 61508/IEC 61511

MPNs 282274, PEP282274, KFU8-UFC-1.D.FA
HS Code 90318000
Weight 0.3 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

USD731.49

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of PEPPERL+FUCHS
Free express shipping to United States
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Request your tailored technical service

Rely on our expert technical team for a range of personalized services: repair, programming, maintenance, and much more.

Product information

Description

Datasheet excerpt: Technical data of  KFU8-UFC-1.D.FA General specifications Signal typeDigital Input Functional safety related parameters Safety Integrity Level (SIL)SIL 2 Supply Connectionterminals 23, 24 Rated voltage20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz Power dissipation/power consumption≤ 2 W ; 2.5 VA / 2.2 W ; 3 VA Interface Programming interfaceprogramming socket Input Connection sidefield side ConnectionInput I: 2-wire sensor: terminals 1+, 3- three wire sensor: terminals 1+, 2- and 3 input II: terminals 13+, 14- start-up override; Input I2- or 3-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact Open circuit voltage/short-circuit current22 V / 40 mA Input resistance4.7 kΩ Switching point/switching hysteresislogic 1: > 2.5 mA ; logic 0: < 1.9 mA Pulse duration> 50 µs Input frequency0.001 ... 10000 Hz Line fault detectionbreakage I ≤ 0.15 mA; short-circuit I > 4 mA Input IIstartup override: 1 ... 1000 s, adjustable in steps of 1 s Active/PassiveI > 4 mA (for min. 100 ms) / I < 1.5 mA Open circuit voltage/short-circuit current18 V / 5 mA Output Connection sidecontrol side Connectionoutput I: terminals 10, 11, 12output II: terminals 16, 17, 18outout III: terminasl 19+, 20-output IV: terminals 8+, 7- Output I, IIsignal, relay Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A Mechanical life5 x 107 switching cycles Energized/De-energized delay20 ms / 20 ms Output IIIelectronic output, passive Contact loading40 V DC Signal level1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: blocked output (off-state current ≤ 10 µA) Output IVanalog Current range0 ... 20 mA or 4 ... 20 mA Open loop voltagemax. 24 V DC Loadmax. 650 Ω Fault signaldownscale I ≤ 3.6 mA , upscale ≥ 21.5 mA (acc. NAMUR NE43) Transfer characteristics Input I Measurement range0.001 ... 10000 Hz Resolution0.1 % of the measurement value , ≥ 0.001 Hz Accuracy0.1 % of the measurement value , > 0.001 Hz Measuring time< 100 ms Influence of ambient temperature0.003 %/K (30 ppm) Output I, II Response delay≤ 200 ms Output IV Resolution< 10 µA Accuracy< 20 µA Influence of ambient temperature0.005 %/K (50 ppm) Galvanic isolation Input I/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Mutual output I, II, IIIreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III/IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Output IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Start-up override/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/output IIIbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Indicators/settings Display elementsLEDs , display Control elementsControl panel Configurationvia operating buttons via PACTware Labelingspace for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61326-1:2006 Low voltage Directive 2014/35/EUEN 61010-1:2010 Conformity Electromagnetic compatibilityNE 21:2006 Degree of protectionIEC 60529:2001 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Mechanical specifications Degree of protectionIP20 Connectionscrew terminals Mass300 g Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C2 Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001 General information Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. Classifications SystemClasscode ECLASS 11.027210128 ECLASS 10.0.127210128 ECLASS 9.027210128 ECLASS 8.027210190 ECLASS 5.127210121 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007 Datasheet excerpt: Technical data of  KFU8-UFC-1.D.FA General specifications Signal typeDigital Input Functional safety related parameters Safety Integrity Level (SIL)SIL 2 Supply Connectionterminals 23, 24 Rated voltage20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz Power dissipation/power consumption≤ 2 W ; 2.5 VA / 2.2 W ; 3 VA Interface Programming interfaceprogramming socket Input Connection sidefield side ConnectionInput I: 2-wire sensor: terminals 1+, 3- three wire sensor: terminals 1+, 2- and 3 input II: terminals 13+, 14- start-up override; Input I2- or 3-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact Open circuit voltage/short-circuit current22 V / 40 mA Input resistance4.7 kΩ Switching point/switching hysteresislogic 1: > 2.5 mA ; logic 0: < 1.9 mA Pulse duration> 50 µs Input frequency0.001 ... 10000 Hz Line fault detectionbreakage I ≤ 0.15 mA; short-circuit I > 4 mA Input IIstartup override: 1 ... 1000 s, adjustable in steps of 1 s Active/PassiveI > 4 mA (for min. 100 ms) / I < 1.5 mA Open circuit voltage/short-circuit current18 V / 5 mA Output Connection sidecontrol side Connectionoutput I: terminals 10, 11, 12output II: terminals 16, 17, 18outout III: terminasl 19+, 20-output IV: terminals 8+, 7- Output I, IIsignal, relay Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A Mechanical life5 x 107 switching cycles Energized/De-energized delay20 ms / 20 ms Output IIIelectronic output, passive Contact loading40 V DC Signal level1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: blocked output (off-state current ≤ 10 µA) Output IVanalog Current range0 ... 20 mA or 4 ... 20 mA Open loop voltagemax. 24 V DC Loadmax. 650 Ω Fault signaldownscale I ≤ 3.6 mA , upscale ≥ 21.5 mA (acc. NAMUR NE43) Transfer characteristics Input I Measurement range0.001 ... 10000 Hz Resolution0.1 % of the measurement value , ≥ 0.001 Hz Accuracy0.1 % of the measurement value , > 0.001 Hz Measuring time< 100 ms Influence of ambient temperature0.003 %/K (30 ppm) Output I, II Response delay≤ 200 ms Output IV Resolution< 10 µA Accuracy< 20 µA Influence of ambient temperature0.005 %/K (50 ppm) Galvanic isolation Input I/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Mutual output I, II, IIIreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III/IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Output IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Start-up override/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/output IIIbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Indicators/settings Display elementsLEDs , display Control elementsControl panel Configurationvia operating buttons via PACTware Labelingspace for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61326-1:2006 Low voltage Directive 2014/35/EUEN 61010-1:2010 Conformity Electromagnetic compatibilityNE 21:2006 Degree of protectionIEC 60529:2001 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Mechanical specifications Degree of protectionIP20 Connectionscrew terminals Mass300 g Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C2 Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001 General information Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. Classifications SystemClasscode ECLASS 11.027210128 ECLASS 10.0.127210128 ECLASS 9.027210128 ECLASS 8.027210190 ECLASS 5.127210121 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007