VBA-2E-G11-I/U/PT100-F PEPPERL+FUCHS - Part number: 222331
Out of Stock - Backorder
To order from manufacturer
EUR 341.45

Import Taxes Excluded

You must be logged

VBA-2E-G11-I/U/PT100-F PEPPERL+FUCHS - Part number: 222331

PEPPERL+FUCHS

AS-Interface analog module VBA-2E-G11-I/U/PT100-F VBA-2E-G11-I/U/PT100-F Addressing jack Function display for bus, internal and external sensor power supply, inputs Supply for inputs from AS-Interface or auxiliary voltage Degree of protection IP68 / IP69K Accuracy ± 0.1 % Integrated shielding Channel-specific input monitoring Inputs for current, voltage or Pt100 temperature sensor AS-Interface analog module VBA-2E-G11-I/U/PT100-F VBA-2E-G11-I/U/PT100-F Addressing jack Function display for bus, internal and external sensor power supply, inputs Supply for inputs from AS-Interface or auxiliary voltage Degree of protection IP68 / IP69K Accuracy ± 0.1 % Integrated shielding Channel-specific input monitoring Inputs for current, voltage or Pt100 temperature sensor

MPNs 222331, PEP222331, VBA-2E-G11-I/U/PT100-F
HS Code 85371091
Weight 0.2 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

EUR 341.45

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of PEPPERL+FUCHS
Free express shipping to United States
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Request your tailored technical service

Rely on our expert technical team for a range of personalized services: repair, programming, maintenance, and much more.

Product information

Description

Datasheet excerpt: Technical data of  VBA-2E-G11-I/U/PT100-F Product Description G11 analog module2 analog inputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd190 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED AS-i/FAULTStatus display; multi-colour LEDGreen: normal operationRed: communication faultFlashing yellow/red: address 0Flashing green/red: peripheral fault LED ANALOGstatus of input signal; LED yellowoff: not activeon: signal within measurement rangeflashing: signal outside of measurement range LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INT/EXTstatus display input supply; LED greengreen: input supply from AS-Interfaceoff: input supply from auxiliary voltage Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 60 mA (without sensors) / max. 200 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type2 analog inputsCurrent: 0 ... 20 mA/4 ... 20 mAvoltage: 0 ... 10 V Pt100: -200 ... 850 °C Supplyfrom AS-Interface (switch position INT, default settings) or auxiliary voltage UEXT (switch position EXT) Current loading capacity≤ 140 mA from AS-Interface; overload and short-circuit resistant ≤ 600 mA from external auxiliary voltage UAUX , overload and short-circuit protected Input resistancecurrent input: max. 70 Ω voltage input: 100 kΩ Measuring currentfor Pt100: 1 mA AccuracyVoltage/current: 0.1% of accumulated value Pt100: 0.1% of indicated temperature [°C] + 0.3 °C Resolution16 Bit / 1 µA (current input) or16 bit / 1 mV (voltage input) or16 Bit / 0.1°C (temperature input) Temperature influenceVoltage/current: 20 ppm/KPt100: (10 ppm of indicated temperature [°C] + 0.003 °C)/K Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.3.D IO code7 ID code3 ID1 codeF ID2 codeD Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P050/60 Hz filterP0=1, enabledP0=0, disabled P1projecting of the 2nd channelP1=1, channel 2 is projectedP1=0, channel 2 is not projected P2Indication of the peripheral fault by exceeding measuring rangeP2=1, peripheral fault is reportedP2=0, peripheral fault is not reported P3P3=1, normal operating modeP3=0, both channels in current mode and without recognition of wire breakage Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP68 / IP69K ConnectionAS-Interface/UAUX: cable piercing method, flat cable yellow/flat cable black Inputs: M12 round connector Material HousingPBT PC Mounting screwStainless steel 1.4305 / AISI 303 Mass200 g Tightening torque, housing screws1.8 Nm Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-2E-G11-I/U/PT100-F Product Description G11 analog module2 analog inputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd190 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED AS-i/FAULTStatus display; multi-colour LEDGreen: normal operationRed: communication faultFlashing yellow/red: address 0Flashing green/red: peripheral fault LED ANALOGstatus of input signal; LED yellowoff: not activeon: signal within measurement rangeflashing: signal outside of measurement range LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INT/EXTstatus display input supply; LED greengreen: input supply from AS-Interfaceoff: input supply from auxiliary voltage Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 60 mA (without sensors) / max. 200 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type2 analog inputsCurrent: 0 ... 20 mA/4 ... 20 mAvoltage: 0 ... 10 V Pt100: -200 ... 850 °C Supplyfrom AS-Interface (switch position INT, default settings) or auxiliary voltage UEXT (switch position EXT) Current loading capacity≤ 140 mA from AS-Interface; overload and short-circuit resistant ≤ 600 mA from external auxiliary voltage UAUX , overload and short-circuit protected Input resistancecurrent input: max. 70 Ω voltage input: 100 kΩ Measuring currentfor Pt100: 1 mA AccuracyVoltage/current: 0.1% of accumulated value Pt100: 0.1% of indicated temperature [°C] + 0.3 °C Resolution16 Bit / 1 µA (current input) or16 bit / 1 mV (voltage input) or16 Bit / 0.1°C (temperature input) Temperature influenceVoltage/current: 20 ppm/KPt100: (10 ppm of indicated temperature [°C] + 0.003 °C)/K Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.3.D IO code7 ID code3 ID1 codeF ID2 codeD Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P050/60 Hz filterP0=1, enabledP0=0, disabled P1projecting of the 2nd channelP1=1, channel 2 is projectedP1=0, channel 2 is not projected P2Indication of the peripheral fault by exceeding measuring rangeP2=1, peripheral fault is reportedP2=0, peripheral fault is not reported P3P3=1, normal operating modeP3=0, both channels in current mode and without recognition of wire breakage Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP68 / IP69K ConnectionAS-Interface/UAUX: cable piercing method, flat cable yellow/flat cable black Inputs: M12 round connector Material HousingPBT PC Mounting screwStainless steel 1.4305 / AISI 303 Mass200 g Tightening torque, housing screws1.8 Nm Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535

Our Company Reviews