VBG-DN-K20-DMD PEPPERL+FUCHS - Part number: 190325
Available on request

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

VBG-DN-K20-DMD PEPPERL+FUCHS - Part number: 190325

PEPPERL+FUCHS

AS-Interface gateway VBG-DN-K20-DMD VBG-DN-K20-DMD Gateway compliant with AS-Interface specification 3.0 2 AS-Interface networks Dublicate addressing detection Earth fault detection AS-Interface noise detection Easy commissioning by graphic display Commissioning, locally on the gateway or via AS-i Control Tools software Fault diagnosis via LEDs and grafic display AS-Interface monitor or extended AS-Interface diagnostic read via display Ethernet diagnostic interface AS-Interface gateway VBG-DN-K20-DMD VBG-DN-K20-DMD Gateway compliant with AS-Interface specification 3.0 2 AS-Interface networks Dublicate addressing detection Earth fault detection AS-Interface noise detection Easy commissioning by graphic display Commissioning, locally on the gateway or via AS-i Control Tools software Fault diagnosis via LEDs and grafic display AS-Interface monitor or extended AS-Interface diagnostic read via display Ethernet diagnostic interface

MPNs 190325, PEP190325, VBG-DN-K20-DMD
HS Code 85176900
Weight 0.52 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Available on request

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Request your tailored technical service

Rely on our expert technical team for a range of personalized services: repair, programming, maintenance, and much more.

Product information

Description

Datasheet excerpt: Technical data of  VBG-DN-K20-DMD Product Description DeviceNet Gateway, double master for 2 AS-Interface networks General specifications AS-Interface specificationV3.0 PLC-Functionalityactivateable Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green LED MNSModule/net status; LED green/red Switch SETSelection and setting of a slave address OK buttonMode selection traditional-graphical/confirmation Button MODEMode selection PRJ-operation/save configuration/cursor ESC buttonMode selection traditional-graphical/cancel Electrical specifications Insulation voltage≥ 500 V Rated operating voltagefrom AS-Interface Rated operating current≤ 200 mA from AS-Interface circuit 1≤ 70 mA from AS-Interface circuit 2 Interface 1 ProtocolDeviceNet Interface 2 Interface typeRS 232, serial Diagnostic Interface Transfer rate19,2 kBit/s Connection AS-Interfacespring terminals, removable DeviceNet5-pin CombiCon connector according to DeviceNet specification Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2001, EN 50295:1999 Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Approvals and certificates EAC conformityTR CU 020/2011 UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Mass520 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBG-DN-K20-DMD Product Description DeviceNet Gateway, double master for 2 AS-Interface networks General specifications AS-Interface specificationV3.0 PLC-Functionalityactivateable Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green LED MNSModule/net status; LED green/red Switch SETSelection and setting of a slave address OK buttonMode selection traditional-graphical/confirmation Button MODEMode selection PRJ-operation/save configuration/cursor ESC buttonMode selection traditional-graphical/cancel Electrical specifications Insulation voltage≥ 500 V Rated operating voltagefrom AS-Interface Rated operating current≤ 200 mA from AS-Interface circuit 1≤ 70 mA from AS-Interface circuit 2 Interface 1 ProtocolDeviceNet Interface 2 Interface typeRS 232, serial Diagnostic Interface Transfer rate19,2 kBit/s Connection AS-Interfacespring terminals, removable DeviceNet5-pin CombiCon connector according to DeviceNet specification Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2001, EN 50295:1999 Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Approvals and certificates EAC conformityTR CU 020/2011 UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Mass520 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121535

Our Company Reviews