RLK61-8-1000-Z/31/135 PEPPERL+FUCHS - Part number: 911608
Available on request

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

RLK61-8-1000-Z/31/135 PEPPERL+FUCHS - Part number: 911608

PEPPERL+FUCHS

Diffuse mode sensor RLK61-8-1000-Z/31/135 RLK61-8-1000-Z/31/135 Cost-optimized series for standard tasks in a special design Compact design Wide range of mounting options thanks to cubic housing design with M30 thread 360° high visibility LEDs Programmable ON-delay, OFF-delay, and One-shot timers Version for universal voltages Relay output Diffuse mode sensor RLK61-8-1000-Z/31/135 RLK61-8-1000-Z/31/135 Cost-optimized series for standard tasks in a special design Compact design Wide range of mounting options thanks to cubic housing design with M30 thread 360° high visibility LEDs Programmable ON-delay, OFF-delay, and One-shot timers Version for universal voltages Relay output

MPNs 911608, PEP911608, RLK61-8-1000-Z/31/135
HS Code 85365000
Weight 0.14 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Available on request

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

Datasheet excerpt: Technical data of  RLK61-8-1000-Z/31/135 Product Description Diffuse mode sensor General specifications Detection range0 ... 1000 mm adjustable Adjustment range120 ... 1000 mm Reference targetstandard white 200 mm x 200 mm Light sourceIRED Light typemodulated infrared light , 850 nm Diameter of the light spot17 mm at a distance of 1000 mm Opening angle1 ° Optical facefrontal Ambient light limit5000 Lux ; according EN 60947-5-2 Indicators/operating means Operation indicator2 LEDs green Function indicator2 LEDs yellow lights up when receiving the light beam ; flashes when falling short of the stability control; OFF: object outside the sensing range Control elementsLight-on/dark-on changeover switch Control elementsSensing range adjuster Control elementsTime adjuster ( 0 ... 10 s ) Electrical specifications Operating voltage24 ... 240 V AC 12 ... 240 V DC No-load supply current≤ 35 mA Protection classII , rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit basis insulation of input circuit according to EN 50178, rated insulation voltage 240 V AC Power consumption≤ 2 VA Output Switching typelight/dark on, switchable Signal output1 SPDT relay Switching voltagemax. 250 V AC/DC Switching currentmax. 3 A Switching powerDC: max. 150 W AC: max. 750 VA Switching frequency20 Hz Response time≤ 25 ms Timer functionDIP switch for selection of operating modes Compliance with standards and directives Directive conformity EMC Directive 2004/108/ECEN 60947-5-2:2007+A1:2012 Standard conformity Product standardEN 60947-5-2:2007 IEC 60947-5-2:2007 StandardsEN 50178, UL 508 Approvals and certificates EAC conformityTR CU 020/2011 TR CU 004/2011 UL approvalcULus Listed, Type 1 enclosure For overcurrent protection, install a fuse with a rated current of max. 5 A and min. 240 V AC/DC CCC approvalCertified by China Compulsory Certification (CCC) Ambient conditions Ambient temperature-40 ... 55 °C (-40 ... 131 °F) Storage temperature-40 ... 70 °C (-40 ... 158 °F) Mechanical specifications Housing width45 mm Housing height73.7 mm Housing depth48.6 mm Degree of protectionIP67 Connection5-pin V95 connector (7/8"-16 UN 2A) Material HousingPC (Polycarbonate) Optical facePMMA Mass140 g Tightening torque, fastening screwsmax. 2 Nm Classifications SystemClasscode ECLASS 11.027270903 ECLASS 10.0.127270903 ECLASS 9.027270903 ECLASS 8.027270903 ECLASS 5.127270903 ETIM 8.0EC001821 ETIM 7.0EC001821 ETIM 6.0EC001821 ETIM 5.0EC001821 UNSPSC 12.139121528 Datasheet excerpt: Technical data of  RLK61-8-1000-Z/31/135 Product Description Diffuse mode sensor General specifications Detection range0 ... 1000 mm adjustable Adjustment range120 ... 1000 mm Reference targetstandard white 200 mm x 200 mm Light sourceIRED Light typemodulated infrared light , 850 nm Diameter of the light spot17 mm at a distance of 1000 mm Opening angle1 ° Optical facefrontal Ambient light limit5000 Lux ; according EN 60947-5-2 Indicators/operating means Operation indicator2 LEDs green Function indicator2 LEDs yellow lights up when receiving the light beam ; flashes when falling short of the stability control; OFF: object outside the sensing range Control elementsLight-on/dark-on changeover switch Control elementsSensing range adjuster Control elementsTime adjuster ( 0 ... 10 s ) Electrical specifications Operating voltage24 ... 240 V AC 12 ... 240 V DC No-load supply current≤ 35 mA Protection classII , rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit basis insulation of input circuit according to EN 50178, rated insulation voltage 240 V AC Power consumption≤ 2 VA Output Switching typelight/dark on, switchable Signal output1 SPDT relay Switching voltagemax. 250 V AC/DC Switching currentmax. 3 A Switching powerDC: max. 150 W AC: max. 750 VA Switching frequency20 Hz Response time≤ 25 ms Timer functionDIP switch for selection of operating modes Compliance with standards and directives Directive conformity EMC Directive 2004/108/ECEN 60947-5-2:2007+A1:2012 Standard conformity Product standardEN 60947-5-2:2007 IEC 60947-5-2:2007 StandardsEN 50178, UL 508 Approvals and certificates EAC conformityTR CU 020/2011 TR CU 004/2011 UL approvalcULus Listed, Type 1 enclosure For overcurrent protection, install a fuse with a rated current of max. 5 A and min. 240 V AC/DC CCC approvalCertified by China Compulsory Certification (CCC) Ambient conditions Ambient temperature-40 ... 55 °C (-40 ... 131 °F) Storage temperature-40 ... 70 °C (-40 ... 158 °F) Mechanical specifications Housing width45 mm Housing height73.7 mm Housing depth48.6 mm Degree of protectionIP67 Connection5-pin V95 connector (7/8"-16 UN 2A) Material HousingPC (Polycarbonate) Optical facePMMA Mass140 g Tightening torque, fastening screwsmax. 2 Nm Classifications SystemClasscode ECLASS 11.027270903 ECLASS 10.0.127270903 ECLASS 9.027270903 ECLASS 8.027270903 ECLASS 5.127270903 ETIM 8.0EC001821 ETIM 7.0EC001821 ETIM 6.0EC001821 ETIM 5.0EC001821 UNSPSC 12.139121528