Retroreflective sensor RL91-54-RT/25/38a/73c RL91-54-RT/25/38a/73c Retroreflective sensor for single-beam closing edge protection Narrow housing suitable for small gaps Sturdy plastic housing Various possibilities for mounting Version with red light Version for supply voltage of up to 30 V DC Retroreflective sensor RL91-54-RT/25/38a/73c RL91-54-RT/25/38a/73c Retroreflective sensor for single-beam closing edge protection Narrow housing suitable for small gaps Sturdy plastic housing Various possibilities for mounting Version with red light Version for supply voltage of up to 30 V DC

MPNs 419071, PEP419071, RL91-54-RT/25/38a/73c
HS Code 85365090
Weight 0.1 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Available on request

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

Datasheet excerpt: Technical data of  RL91-54-RT/25/38a/73c Product Description Mid-range photoelectric sensors for detecting people, objects, and vehicles General specifications Effective detection range0 ... 4 m Reflector distance0.2 ... 4000 mm Threshold detection range8 m Reference targetH85-2 reflector Light sourceLED Light typemodulated visible red light Diameter of the light spot160 mm at a distance of 4000 mm Opening angle2.5 ° Ambient light limit90000 Lux Functional safety related parameters MTTFd1083.4 a Indicators/operating means Function indicatorLED red, flashes when falling short of the stability control Electrical specifications Operating voltage12 ... 30 V DC / 18 ... 28 V AC No-load supply current< 100 mA Output Switching typelight-on Signal outputWeak current relay, 1 alternator Switching voltage≤ 55 V AC / 24 V DC Switching current1 A /24 V DC, 0.5 A /110 V AC Switching powermax. 24 W / 55 VA Switching frequency25 Hz Response time20 ms Conformity Product standardEN 60947-5-2 Approvals and certificates UL approvalcULus CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-20 ... 55 °C (-4 ... 131 °F) Storage temperature-20 ... 75 °C (-4 ... 167 °F) Mechanical specifications Degree of protectionIP65 Connection4-pin, M12 x 1 connector Material HousingLuran® Optical faceglass pane Mass100 g NoteSafety fuse ≤ 315 mA (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. Classifications SystemClasscode ECLASS 11.027270902 ECLASS 10.0.127270902 ECLASS 9.027270902 ECLASS 8.027270902 ECLASS 5.127270902 ETIM 8.0EC002717 ETIM 7.0EC002717 ETIM 6.0EC002717 ETIM 5.0EC002717 UNSPSC 12.139121528 Datasheet excerpt: Technical data of  RL91-54-RT/25/38a/73c Product Description Mid-range photoelectric sensors for detecting people, objects, and vehicles General specifications Effective detection range0 ... 4 m Reflector distance0.2 ... 4000 mm Threshold detection range8 m Reference targetH85-2 reflector Light sourceLED Light typemodulated visible red light Diameter of the light spot160 mm at a distance of 4000 mm Opening angle2.5 ° Ambient light limit90000 Lux Functional safety related parameters MTTFd1083.4 a Indicators/operating means Function indicatorLED red, flashes when falling short of the stability control Electrical specifications Operating voltage12 ... 30 V DC / 18 ... 28 V AC No-load supply current< 100 mA Output Switching typelight-on Signal outputWeak current relay, 1 alternator Switching voltage≤ 55 V AC / 24 V DC Switching current1 A /24 V DC, 0.5 A /110 V AC Switching powermax. 24 W / 55 VA Switching frequency25 Hz Response time20 ms Conformity Product standardEN 60947-5-2 Approvals and certificates UL approvalcULus CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-20 ... 55 °C (-4 ... 131 °F) Storage temperature-20 ... 75 °C (-4 ... 167 °F) Mechanical specifications Degree of protectionIP65 Connection4-pin, M12 x 1 connector Material HousingLuran® Optical faceglass pane Mass100 g NoteSafety fuse ≤ 315 mA (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. Classifications SystemClasscode ECLASS 11.027270902 ECLASS 10.0.127270902 ECLASS 9.027270902 ECLASS 8.027270902 ECLASS 5.127270902 ETIM 8.0EC002717 ETIM 7.0EC002717 ETIM 6.0EC002717 ETIM 5.0EC002717 UNSPSC 12.139121528