MV11-Ex/40b/112 PEPPERL+FUCHS - Part number: 108993

PEPPERL+FUCHS

Thru-beam sensor M11/MV11-Ex/40b/112 M11/MV11-Ex/40b/112 ATEX approval for zone 1 (Gas) Intrinsically safe, Ex op is ia IIC T6 Gb Adjustable sensitivity Thru-beam sensor M11/MV11-Ex/40b/112 M11/MV11-Ex/40b/112 ATEX approval for zone 1 (Gas) Intrinsically safe, Ex op is ia IIC T6 Gb Adjustable sensitivity

MPNs 108993, PEP108993, MV11-Ex/40b/112
HS Code 85365000
Weight 0.06 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

1 Available from partners Price and delivery upon quote request
You must be logged

Request your tailored technical service

Rely on our expert technical team for a range of personalized services: repair, programming, maintenance, and much more.

Product information

Description

Datasheet excerpt: Technical data of  M11/MV11-Ex/40b/112 Product Description NAMUR thru-beam sensor, small housing design, 10 m detection range, red light, light/dark on, DC version, NAMUR output, M12 plug General specifications Effective detection range0 ... 10 m Threshold detection range10 m Light sourceLED Light typemodulated visible red light , 660 nm Ambient light limit≤ 10000 Lux sun light ≤ 7500 Lux halogen light Functional safety related parameters MTTFd575 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Operation indicatorLED green: power on (emitter) Function indicatorLED yellow: switching state (receiver) Control elementssensitivity adjustment Electrical specifications Operating voltage6 ... 15.5 V DC (Ri approx. 0 Ohm) Ripple5 % Power consumptionmax. 64 mW Time delay before availability20 ms Output Switching typelight/dark on, programmable Signal output1 NAMUR output NC/NO programmable Switching voltage8 V DC (Ri approx. 1 kΩ) Switching frequency≤ 100 Hz Current consumptionEmitter: ≥ 2.2 mA , Receiver: Reference target detectedconnection 1, 2: ≥ 2.2 mA connection 1, 4: ≤ 1 mA Reference target not detectedconnection 1, 2: ≤ 1 mA connection 1, 4: ≥ 2.2 mA Response time5 ms Conformity Product standardEN 60947-5-2 Approvals and certificates CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 80 °C (-40 ... 176 °F) Mechanical specifications Housing width18 mm Housing height50 mm Housing depth45 mm Degree of protectionIP67 ConnectionV1 connector (M12 x 1), 4-pin, rotatable through 90° Material HousingPBT Optical facescratch resistant plastic lens Mass60 g (device) ATEX G EC-Type Examination CertificatePTB 99 ATEX 2036X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany CE markingCE0102 ATEX markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb Directive conformity2014/34/EU StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 Effective internal capacitance Cimax. 110 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. IECEx G Certificate numberIECEx PTB 12.0061 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany IECEx markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb StandardsIEC 60079-0:2011 IEC 60079-11:2011 IEC 60079-28:2006 Effective internal capacitance Cimax. 110 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. Classifications SystemClasscode ECLASS 11.027270901 ECLASS 10.0.127270901 ECLASS 9.027270901 ECLASS 8.027270901 ECLASS 5.127270901 ETIM 8.0EC002716 ETIM 7.0EC002716 ETIM 6.0EC002716 ETIM 5.0EC002716 UNSPSC 12.139121528 Datasheet excerpt: Technical data of  M11/MV11-Ex/40b/112 Product Description NAMUR thru-beam sensor, small housing design, 10 m detection range, red light, light/dark on, DC version, NAMUR output, M12 plug General specifications Effective detection range0 ... 10 m Threshold detection range10 m Light sourceLED Light typemodulated visible red light , 660 nm Ambient light limit≤ 10000 Lux sun light ≤ 7500 Lux halogen light Functional safety related parameters MTTFd575 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Operation indicatorLED green: power on (emitter) Function indicatorLED yellow: switching state (receiver) Control elementssensitivity adjustment Electrical specifications Operating voltage6 ... 15.5 V DC (Ri approx. 0 Ohm) Ripple5 % Power consumptionmax. 64 mW Time delay before availability20 ms Output Switching typelight/dark on, programmable Signal output1 NAMUR output NC/NO programmable Switching voltage8 V DC (Ri approx. 1 kΩ) Switching frequency≤ 100 Hz Current consumptionEmitter: ≥ 2.2 mA , Receiver: Reference target detectedconnection 1, 2: ≥ 2.2 mA connection 1, 4: ≤ 1 mA Reference target not detectedconnection 1, 2: ≤ 1 mA connection 1, 4: ≥ 2.2 mA Response time5 ms Conformity Product standardEN 60947-5-2 Approvals and certificates CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 80 °C (-40 ... 176 °F) Mechanical specifications Housing width18 mm Housing height50 mm Housing depth45 mm Degree of protectionIP67 ConnectionV1 connector (M12 x 1), 4-pin, rotatable through 90° Material HousingPBT Optical facescratch resistant plastic lens Mass60 g (device) ATEX G EC-Type Examination CertificatePTB 99 ATEX 2036X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany CE markingCE0102 ATEX markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb Directive conformity2014/34/EU StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 Effective internal capacitance Cimax. 110 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. IECEx G Certificate numberIECEx PTB 12.0061 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany IECEx markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb StandardsIEC 60079-0:2011 IEC 60079-11:2011 IEC 60079-28:2006 Effective internal capacitance Cimax. 110 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. Classifications SystemClasscode ECLASS 11.027270901 ECLASS 10.0.127270901 ECLASS 9.027270901 ECLASS 8.027270901 ECLASS 5.127270901 ETIM 8.0EC002716 ETIM 7.0EC002716 ETIM 6.0EC002716 ETIM 5.0EC002716 UNSPSC 12.139121528

Our Company Reviews