NCN3-F31K-N5-K PEPPERL+FUCHS - Part number: 233552
Out of Stock - Backorder
To order from manufacturer
USD255.82

Import Taxes Excluded

You must be logged

NCN3-F31K-N5-K PEPPERL+FUCHS - Part number: 233552

PEPPERL+FUCHS

Inductive sensor NCN3-F31K-N5-K NCN3-F31K-N5-K Direct mounting on standard actuators Fixed setting 2:1 transfer method LEDs for switching state of sensor and solenoid valve Valve LEDs disconnectable ATEX & IECEX certifications NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers Inductive sensor NCN3-F31K-N5-K NCN3-F31K-N5-K Direct mounting on standard actuators Fixed setting 2:1 transfer method LEDs for switching state of sensor and solenoid valve Valve LEDs disconnectable ATEX & IECEX certifications NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers

MPNs 233552, PEP233552, NCN3-F31K-N5-K
HS Code 85365090
Weight N/A

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

USD255.82

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of PEPPERL+FUCHS
Free express shipping to United States
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

Datasheet excerpt: Technical data of  NCN3-F31K-N5-K General specifications Switching function2 x normally closed (NC) Output typeNAMUR Rated operating distance3 mm Installationflush mountable Assured operating distance0 ... 2.4 mm Actual operating distance2.7 ... 3.3 mm typ. Reduction factor rAl 0.35 Reduction factor rCu 0.3 Reduction factor r304 0.75 Reduction factor rSt37 1 Reduction factor rBrass 0.45 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 3 kHz Hysteresistyp. 5 % Short-circuit protectionyes Suitable for 2:1 technologyyes , Reverse polarity protection diode not required Current consumption Measuring plate not detected≥ 3 mA Measuring plate detected≤ 1 mA Time delay before availability≤ 1.1 ms Switching state indicatorLED, yellow Valve status indicatorLED, yellow Functional safety related parameters MTTFd1470 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Valve circuit Voltagemax. 32 V DC Currentmax. 240 mA Short-circuit protectionno Reverse polarity protectionyes, with reversed output LED is out of function, therfore more power for solenoid valve Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibilityNE 21:2007 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx TUN 17.0021X Equipment protection level GbIECEx TUN 17.0021X Equipment protection level MbIECEx TUN 17.0021X ATEX approval Equipment protection level GaTÜV 99 ATEX 1479 X Equipment protection level GbTÜV 99 ATEX 1479 X Equipment protection level Gc (ic)PF13CERT2895 X UL approvalcULus Listed, General Purpose Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0456 CSA approvalcCSAus Listed, General Purpose Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection (system side)Cage tension spring terminals Stripped length 7 mm M20 x 1.5 cable gland usable thread length 11.5 mm screw-in depth max. 11.5 mm Core cross section (system side)1.5/2.5 mm2 flexible/rigid Connection (valve side)Cage tension spring terminals Core cross section (valve side)1.5/2.5 mm2 flexible/rigid Housing materialPBT Sensing facePBT Degree of protectionIP67 Tightening torque, fastening screws4 Nm ... 5 Nm Tightening torque, housing screws1 Nm Tightening torque, cable glandM20 x 1.5 ; max. 7 Nm M12 x 1.5 ; max. 1.5 Nm NoteLED switch-off General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027220501 ECLASS 10.0.127220501 ECLASS 9.027220501 ECLASS 8.027220501 ECLASS 5.127220501 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  NCN3-F31K-N5-K General specifications Switching function2 x normally closed (NC) Output typeNAMUR Rated operating distance3 mm Installationflush mountable Assured operating distance0 ... 2.4 mm Actual operating distance2.7 ... 3.3 mm typ. Reduction factor rAl 0.35 Reduction factor rCu 0.3 Reduction factor r304 0.75 Reduction factor rSt37 1 Reduction factor rBrass 0.45 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 3 kHz Hysteresistyp. 5 % Short-circuit protectionyes Suitable for 2:1 technologyyes , Reverse polarity protection diode not required Current consumption Measuring plate not detected≥ 3 mA Measuring plate detected≤ 1 mA Time delay before availability≤ 1.1 ms Switching state indicatorLED, yellow Valve status indicatorLED, yellow Functional safety related parameters MTTFd1470 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Valve circuit Voltagemax. 32 V DC Currentmax. 240 mA Short-circuit protectionno Reverse polarity protectionyes, with reversed output LED is out of function, therfore more power for solenoid valve Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibilityNE 21:2007 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx TUN 17.0021X Equipment protection level GbIECEx TUN 17.0021X Equipment protection level MbIECEx TUN 17.0021X ATEX approval Equipment protection level GaTÜV 99 ATEX 1479 X Equipment protection level GbTÜV 99 ATEX 1479 X Equipment protection level Gc (ic)PF13CERT2895 X UL approvalcULus Listed, General Purpose Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0456 CSA approvalcCSAus Listed, General Purpose Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection (system side)Cage tension spring terminals Stripped length 7 mm M20 x 1.5 cable gland usable thread length 11.5 mm screw-in depth max. 11.5 mm Core cross section (system side)1.5/2.5 mm2 flexible/rigid Connection (valve side)Cage tension spring terminals Core cross section (valve side)1.5/2.5 mm2 flexible/rigid Housing materialPBT Sensing facePBT Degree of protectionIP67 Tightening torque, fastening screws4 Nm ... 5 Nm Tightening torque, housing screws1 Nm Tightening torque, cable glandM20 x 1.5 ; max. 7 Nm M12 x 1.5 ; max. 1.5 Nm NoteLED switch-off General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027220501 ECLASS 10.0.127220501 ECLASS 9.027220501 ECLASS 8.027220501 ECLASS 5.127220501 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550