PL2-F25-N4-K PEPPERL+FUCHS - Part number: 291802
Out of Stock - Backorder
To order from manufacturer
USD149.41

Import Taxes Excluded

You must be logged

PL2-F25-N4-K PEPPERL+FUCHS - Part number: 291802

PEPPERL+FUCHS

Inductive sensor PL2-F25-N4-K PL2-F25-N4-K For installation in housing PL2... without valve connection ATEX & IECEX certifications NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers Inductive sensor PL2-F25-N4-K PL2-F25-N4-K For installation in housing PL2... without valve connection ATEX & IECEX certifications NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers

MPNs 291802, PEP291802, PL2-F25-N4-K
HS Code 85365090
Weight N/A

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

USD149.41

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of PEPPERL+FUCHS
To United States starting from USD27.36 by DHL Express Worldwide
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

Datasheet excerpt: Technical data of  PL2-F25-N4-K General specifications Switching function2 x normally closed (NC) Output typeNAMUR Rated operating distance3 mm Installationflush mountable Assured operating distance0 ... 2.43 mm Actual operating distance2.7 ... 3.3 mm Reduction factor rAl 0.52 Reduction factor rCu 0.43 Reduction factor r304 0.86 Reduction factor rSt37 1 Reduction factor rBrass 0.54 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Operating voltage5 ... 25 V Switching frequency0 ... 100 Hz Hysteresistyp. 5 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Suitable for 2:1 technologyyes , Reverse polarity protection diode not required Current consumption Measuring plate not detected≥ 3 mA at nominal voltage Measuring plate detected≤ 1 mA at nominal voltage Time delay before availability≤ 1 ms Switching state indicatorLED, yellow Functional safety related parameters MTTFd834 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibilityNE 21:2007 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx TUN 17.0021X Equipment protection level GbIECEx TUN 17.0021X Equipment protection level MbIECEx TUN 17.0021X ATEX approval Equipment protection level GaTÜV 99 ATEX 1479 X Equipment protection level GbTÜV 99 ATEX 1479 X Equipment protection level Gc (ic)PF13CERT2895 X CCC approval Hazardous Location2020322315002262 NEPSI approval NEPSI certificateGYJ19.1410X Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection (system side)Cage tension spring terminals Core cross section (system side)up to 2.5 mm2 Housing materialPBT Sensing facePBT Mass79 g Tightening torque, fastening screws0.3 Nm General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027220501 ECLASS 10.0.127220501 ECLASS 9.027220501 ECLASS 8.027220501 ECLASS 5.127220501 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  PL2-F25-N4-K General specifications Switching function2 x normally closed (NC) Output typeNAMUR Rated operating distance3 mm Installationflush mountable Assured operating distance0 ... 2.43 mm Actual operating distance2.7 ... 3.3 mm Reduction factor rAl 0.52 Reduction factor rCu 0.43 Reduction factor r304 0.86 Reduction factor rSt37 1 Reduction factor rBrass 0.54 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Operating voltage5 ... 25 V Switching frequency0 ... 100 Hz Hysteresistyp. 5 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Suitable for 2:1 technologyyes , Reverse polarity protection diode not required Current consumption Measuring plate not detected≥ 3 mA at nominal voltage Measuring plate detected≤ 1 mA at nominal voltage Time delay before availability≤ 1 ms Switching state indicatorLED, yellow Functional safety related parameters MTTFd834 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibilityNE 21:2007 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx TUN 17.0021X Equipment protection level GbIECEx TUN 17.0021X Equipment protection level MbIECEx TUN 17.0021X ATEX approval Equipment protection level GaTÜV 99 ATEX 1479 X Equipment protection level GbTÜV 99 ATEX 1479 X Equipment protection level Gc (ic)PF13CERT2895 X CCC approval Hazardous Location2020322315002262 NEPSI approval NEPSI certificateGYJ19.1410X Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection (system side)Cage tension spring terminals Core cross section (system side)up to 2.5 mm2 Housing materialPBT Sensing facePBT Mass79 g Tightening torque, fastening screws0.3 Nm General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027220501 ECLASS 10.0.127220501 ECLASS 9.027220501 ECLASS 8.027220501 ECLASS 5.127220501 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550

Our Company Reviews