Standstill and Rotational Direction Monitor KFD2-SR2-2.W.SM KFD2-SR2-2.W.SM 2-channel signal conditioner 24 V DC supply PNP/push-pull, dry contacts or NAMUR inputs Selectable frequency trip values 2 relay contact outputs Start-up override Selectable mode of operation Without line fault detection Up to SIL 2 acc. to IEC/EN 61508 Standstill and Rotational Direction Monitor KFD2-SR2-2.W.SM KFD2-SR2-2.W.SM 2-channel signal conditioner 24 V DC supply PNP/push-pull, dry contacts or NAMUR inputs Selectable frequency trip values 2 relay contact outputs Start-up override Selectable mode of operation Without line fault detection Up to SIL 2 acc. to IEC/EN 61508

MPNs 132965, PEP132965, KFD2-SR2-2.W.SM
HS Code 90318000
Weight 0.15 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

USD342.42

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of PEPPERL+FUCHS
Free express shipping to United States
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Request your tailored technical service

Rely on our expert technical team for a range of personalized services: repair, programming, maintenance, and much more.

Product information

Description

Datasheet excerpt: Technical data of  KFD2-SR2-2.W.SM General specifications Signal typeDigital Input Programmingvia DIP switch and programmable Functional safety related parameters Safety Integrity Level (SIL)SIL 2 Supply Connectionterminals 14+, 15- Rated voltage20 ... 30 V DC Power consumptionmax. 1.5 W Input Connection sidefield side ConnectionInput I: terminals 1+, 2+, 3- ;Input II: terminals 4+, 5+, 6- Rated valuesacc. to EN 60947-5-6 (NAMUR) Open circuit voltage/short-circuit current8 V DC / 8 mA Switching point/switching hysteresis1.2 ... 2.1 mA / 0.2 mA Line fault detectionnot available Control inputsensor power supply 8.2 V, impedance 1.2 kΩ Pulse duration> 200 µs for standstill monitoring,> 250 µs for rotation direction detecion Output Connection sidecontrol side Connectionoutput I: terminals 7, 8, 9 ;output II: terminals 10, 11, 12 Contact loading253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load Minimum switch current2 mA / 24 V DC Energized/De-energized delay20 ms / 20 ms Mechanical life107 switching cycles Trip valuefor standstill monitoring:0.1 Hz; 0.5 Hz; 2 Hz; 10 Hzadjustable via DIP switch (S1 and S2) Transfer characteristics Accuracy5 % (S3 = I), 30 % (S3 = II) Start-up override5 seconds or 20 seconds, programmable Frequency range≤ 2 kHz Rotation direction detection90° phase difference between pulse input signal 1 and 2, overlapping ≥ 125 µs Galvanic isolation Input/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Indicators/settings Display elementsLEDs Control elementsDIP switch Configurationvia DIP switches Labelingspace for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61326-1:2013 (industrial locations) Low voltage Directive 2014/35/EUEN 61010-1:2010 Conformity Electromagnetic compatibilityNE 21:2006 Degree of protectionIEC 60529:2001 InputEN 60947-5-6:2000 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Mechanical specifications Degree of protectionIP20 Connectionscrew terminals Mass150 g Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001 General information Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. Classifications SystemClasscode ECLASS 11.027210128 ECLASS 10.0.127210128 ECLASS 9.027210128 ECLASS 8.027210190 ECLASS 5.127210121 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007 Datasheet excerpt: Technical data of  KFD2-SR2-2.W.SM General specifications Signal typeDigital Input Programmingvia DIP switch and programmable Functional safety related parameters Safety Integrity Level (SIL)SIL 2 Supply Connectionterminals 14+, 15- Rated voltage20 ... 30 V DC Power consumptionmax. 1.5 W Input Connection sidefield side ConnectionInput I: terminals 1+, 2+, 3- ;Input II: terminals 4+, 5+, 6- Rated valuesacc. to EN 60947-5-6 (NAMUR) Open circuit voltage/short-circuit current8 V DC / 8 mA Switching point/switching hysteresis1.2 ... 2.1 mA / 0.2 mA Line fault detectionnot available Control inputsensor power supply 8.2 V, impedance 1.2 kΩ Pulse duration> 200 µs for standstill monitoring,> 250 µs for rotation direction detecion Output Connection sidecontrol side Connectionoutput I: terminals 7, 8, 9 ;output II: terminals 10, 11, 12 Contact loading253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load Minimum switch current2 mA / 24 V DC Energized/De-energized delay20 ms / 20 ms Mechanical life107 switching cycles Trip valuefor standstill monitoring:0.1 Hz; 0.5 Hz; 2 Hz; 10 Hzadjustable via DIP switch (S1 and S2) Transfer characteristics Accuracy5 % (S3 = I), 30 % (S3 = II) Start-up override5 seconds or 20 seconds, programmable Frequency range≤ 2 kHz Rotation direction detection90° phase difference between pulse input signal 1 and 2, overlapping ≥ 125 µs Galvanic isolation Input/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Indicators/settings Display elementsLEDs Control elementsDIP switch Configurationvia DIP switches Labelingspace for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61326-1:2013 (industrial locations) Low voltage Directive 2014/35/EUEN 61010-1:2010 Conformity Electromagnetic compatibilityNE 21:2006 Degree of protectionIEC 60529:2001 InputEN 60947-5-6:2000 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Mechanical specifications Degree of protectionIP20 Connectionscrew terminals Mass150 g Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001 General information Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. Classifications SystemClasscode ECLASS 11.027210128 ECLASS 10.0.127210128 ECLASS 9.027210128 ECLASS 8.027210190 ECLASS 5.127210121 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007

Our Company Reviews