VBG-PBS-K30-DMD PEPPERL+FUCHS - Part number: 220392
Out of Stock - Backorder
To order from manufacturer
USD4,795.00

Import Taxes Excluded

You must be logged

VBG-PBS-K30-DMD PEPPERL+FUCHS - Part number: 220392

PEPPERL+FUCHS

AS-Interface Gateway/Safety Monitor VBG-PBS-K30-DMD VBG-PBS-K30-DMD Gateway and safety monitor in one housing Gateway compliant with AS-Interface specification 3.0 Connection to PROFIBUS DP AS-Interface safety monitor with extended range of functions Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849 Memory card for configuration data 2 AS-Interface networks 2 safe output relays and 2 safe electronic outputs PROFIsafe protocol for centralized and secure higher-level control AS-Interface Gateway/Safety Monitor VBG-PBS-K30-DMD VBG-PBS-K30-DMD Gateway and safety monitor in one housing Gateway compliant with AS-Interface specification 3.0 Connection to PROFIBUS DP AS-Interface safety monitor with extended range of functions Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849 Memory card for configuration data 2 AS-Interface networks 2 safe output relays and 2 safe electronic outputs PROFIsafe protocol for centralized and secure higher-level control

MPNs 220392, PEP220392, VBG-PBS-K30-DMD
HS Code 85176900
Weight 0.8 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

USD4,795.00

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of PEPPERL+FUCHS
Free express shipping to United States
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Request your tailored technical service

Rely on our expert technical team for a range of personalized services: repair, programming, maintenance, and much more.

Product information

Description

Datasheet excerpt: Technical data of  VBG-PBS-K30-DMD Product Description PROFIBUS Gateway, PROFIsafe for 2 AS-Interface networks General specifications AS-Interface specificationV3.0 Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display Switch-on delay< 10 s UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e MTTFd200 a B10d2 E+7 Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED PROFIBUSPROFIBUS master detected; LED green LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX ; LED green LED EDM/StartInput closed, 4x yellow LEDs LED output circuitOutput circuit closed; 4 x green LEDs Button4 Electrical specifications Insulation voltage≥ 500 V Rated operating voltage26.5 ... 31.6 V from AS-Interface; Output K3 and K4 24 V DC Rated operating current≤ 300 mA off AS interface network 1≤ 300 mA off AS interface network 2≤ 370 mA in total Interface 1 Interface typeRS-485 ProtocolPROFIBUS according to DIN 19245 Part 3 Transfer rate9.6 kBit/s / 12 MBit/s , Automatic baud rate detection Interface 2 Interface typeRS 232, serial Diagnostic Interface Transfer rate19,2 kBit/s Interface 3 Interface typeChip card slot Input Number/Type4 EDM/Start inputs:EDM: Inputs for the external device monitoring circuitsStart: start inputs:Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs) Output Safety outputOutput circuits 1 and 2: 2 potential-free contacts,max. contact load:3  ADC-13 at 30 VDC,3 AAC-15 at 30 VACOutput circuits 3 and 4: 2 PNP transistor outputsmax. contact load:0.5  ADC-13 at 30  VDC Connection PROFIBUSSub-D interface AS-Interfacespring terminals, removable Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007 Degree of protectionEN 60529:2000 Fieldbus standardPROFIBUS according to DIN 19245 Part 3 AS-InterfaceEN 62026-2:2013 Shock resistanceEN 61131-2:2004 StandardsEN 61000-6-2:2005, EN 61000-6-4:2007 EN 954-1:1996 (up to Kategorie 4), IEC 61508:2001 and EN 62061:2005 (up to SIL3) EN 13849:2008 (PL e) Approvals and certificates UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Mass800 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121004 Datasheet excerpt: Technical data of  VBG-PBS-K30-DMD Product Description PROFIBUS Gateway, PROFIsafe for 2 AS-Interface networks General specifications AS-Interface specificationV3.0 Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display Switch-on delay< 10 s UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e MTTFd200 a B10d2 E+7 Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED PROFIBUSPROFIBUS master detected; LED green LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX ; LED green LED EDM/StartInput closed, 4x yellow LEDs LED output circuitOutput circuit closed; 4 x green LEDs Button4 Electrical specifications Insulation voltage≥ 500 V Rated operating voltage26.5 ... 31.6 V from AS-Interface; Output K3 and K4 24 V DC Rated operating current≤ 300 mA off AS interface network 1≤ 300 mA off AS interface network 2≤ 370 mA in total Interface 1 Interface typeRS-485 ProtocolPROFIBUS according to DIN 19245 Part 3 Transfer rate9.6 kBit/s / 12 MBit/s , Automatic baud rate detection Interface 2 Interface typeRS 232, serial Diagnostic Interface Transfer rate19,2 kBit/s Interface 3 Interface typeChip card slot Input Number/Type4 EDM/Start inputs:EDM: Inputs for the external device monitoring circuitsStart: start inputs:Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs) Output Safety outputOutput circuits 1 and 2: 2 potential-free contacts,max. contact load:3  ADC-13 at 30 VDC,3 AAC-15 at 30 VACOutput circuits 3 and 4: 2 PNP transistor outputsmax. contact load:0.5  ADC-13 at 30  VDC Connection PROFIBUSSub-D interface AS-Interfacespring terminals, removable Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007 Degree of protectionEN 60529:2000 Fieldbus standardPROFIBUS according to DIN 19245 Part 3 AS-InterfaceEN 62026-2:2013 Shock resistanceEN 61131-2:2004 StandardsEN 61000-6-2:2005, EN 61000-6-4:2007 EN 954-1:1996 (up to Kategorie 4), IEC 61508:2001 and EN 62061:2005 (up to SIL3) EN 13849:2008 (PL e) Approvals and certificates UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Mass800 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121004

Our Company Reviews