Frequency Converter with Direction and Synchronization Monitor KFU8-UFT-2.D.FA KFU8-UFT-2.D.FA 2-channel signal conditioner Universal usage at different power supplies Dry contact or NAMUR inputs Input frequency 1 mHz ... 1 kHz Current output 0/4 mA ... 20 mA Relay contact and transistor output Start-up override Configurable by PACTware or keypad Line fault detection (LFD) Frequency Converter with Direction and Synchronization Monitor KFU8-UFT-2.D.FA KFU8-UFT-2.D.FA 2-channel signal conditioner Universal usage at different power supplies Dry contact or NAMUR inputs Input frequency 1 mHz ... 1 kHz Current output 0/4 mA ... 20 mA Relay contact and transistor output Start-up override Configurable by PACTware or keypad Line fault detection (LFD)

MPNs 192334, PEP192334, KFU8-UFT-2.D.FA
HS Code 90318000
Weight 0.3 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

USD928.21

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of PEPPERL+FUCHS
Free express shipping to United States
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Request your tailored technical service

Rely on our expert technical team for a range of personalized services: repair, programming, maintenance, and much more.

Product information

Description

Datasheet excerpt: Technical data of  KFU8-UFT-2.D.FA General specifications Signal typeDigital Input Supply Connectionterminals 23, 24 Rated voltage20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz Rated current130 mA Power dissipation2.2 W / 3.5 VA Power consumption2.5 W / 4 VA Interface Programming interfaceprogramming socket Input Connection sidefield side Connectioninput I: terminals 1+, 3-input II: terminals 4+, 6- input III: terminals 13+, 14- (control input 1) input IV: terminals 15+, 14- (control input 2) Input I, II2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact Open circuit voltage/short-circuit current8.2 V / 10 mA Switching point/switching hysteresislogic 1: > 2.5 mA ; logic 0: < 1.9 mA Pulse durationmin. 250 µs , overlap on direction of rotation signal: ≥ 125 µs Input frequencyrotation direction monitoring 0.001 ... 1000 Hz slip monitoring 10 ... 1000 Hz Line fault detectionbreakage I ≤ 0.15 mA; short-circuit I > 4 mA Input III, IV Active/PassiveI > 4 mA (for min. 100 ms) / I < 1.5 mA Open circuit voltage/short-circuit current18 V / 5 mA Output Connection sidecontrol side Connectionoutput I: terminals 10, 11, 12 output II: terminals 16, 17, 18 output III: terminals 19+, 20- output IV: terminals 21+, 20- output V: terminals 7-, 8+ Output I, IIsignal, relay Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A Mechanical life5 x 107 switching cycles Energized/De-energized delay20 ms / 20 ms Output III and IVsignal , electronic output, passive Contact loading40 V DC Signal level1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: blocked output (off-state current ≤ 10 µA) Output Vanalog Current range0 ... 20 mA or 4 ... 20 mA Open loop voltagemax. 24 V DC Loadmax. 650 Ω Fault signaldownscale I ≤ 3.6 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43) Programming interface Connectionprogramming socket InterfaceRS 232 Transfer characteristics Input I and II Measurement range0.001 ... 1000 Hz Resolutionslip monitoring: 1% frequency measurement: 0,1% of measured value; but >0.001Hz Accuracyslip monitoring: 1% frequency measurement: 0.5% of measured value; but >0.001Hz Measuring timefrequency measurement: < 100 ms Influence of ambient temperature0.003 %/K (30 ppm) Output I, II Response delay≤ 200 ms Output V Resolution< 10 µA Accuracy< 30 µA Influence of ambient temperature0.005 %/K (50 ppm) Galvanic isolation Input I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Input III, IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Mutual output I, II, IIIreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Mutual output I, II, IV reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III, IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III, IV/input III, IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Output III, IV/Vbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Output V/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/output III, IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Indicators/settings Display elementsLEDs , display Control elementsControl panel Configurationvia operating buttons via PACTware Labelingspace for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61326-1:2006 Low voltage Directive 2014/35/EUEN 61010-1:2010 Conformity Electromagnetic compatibilityNE 21:2006 Degree of protectionIEC 60529:2001 InputEN 60947-5-6:2000 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Mechanical specifications Degree of protectionIP20 Connectionscrew terminals Mass300 g Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C2 Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001 General information Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. Classifications SystemClasscode ECLASS 11.027210128 ECLASS 10.0.127210128 ECLASS 9.027210128 ECLASS 8.027210190 ECLASS 5.127210121 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007 Datasheet excerpt: Technical data of  KFU8-UFT-2.D.FA General specifications Signal typeDigital Input Supply Connectionterminals 23, 24 Rated voltage20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz Rated current130 mA Power dissipation2.2 W / 3.5 VA Power consumption2.5 W / 4 VA Interface Programming interfaceprogramming socket Input Connection sidefield side Connectioninput I: terminals 1+, 3-input II: terminals 4+, 6- input III: terminals 13+, 14- (control input 1) input IV: terminals 15+, 14- (control input 2) Input I, II2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact Open circuit voltage/short-circuit current8.2 V / 10 mA Switching point/switching hysteresislogic 1: > 2.5 mA ; logic 0: < 1.9 mA Pulse durationmin. 250 µs , overlap on direction of rotation signal: ≥ 125 µs Input frequencyrotation direction monitoring 0.001 ... 1000 Hz slip monitoring 10 ... 1000 Hz Line fault detectionbreakage I ≤ 0.15 mA; short-circuit I > 4 mA Input III, IV Active/PassiveI > 4 mA (for min. 100 ms) / I < 1.5 mA Open circuit voltage/short-circuit current18 V / 5 mA Output Connection sidecontrol side Connectionoutput I: terminals 10, 11, 12 output II: terminals 16, 17, 18 output III: terminals 19+, 20- output IV: terminals 21+, 20- output V: terminals 7-, 8+ Output I, IIsignal, relay Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A Mechanical life5 x 107 switching cycles Energized/De-energized delay20 ms / 20 ms Output III and IVsignal , electronic output, passive Contact loading40 V DC Signal level1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: blocked output (off-state current ≤ 10 µA) Output Vanalog Current range0 ... 20 mA or 4 ... 20 mA Open loop voltagemax. 24 V DC Loadmax. 650 Ω Fault signaldownscale I ≤ 3.6 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43) Programming interface Connectionprogramming socket InterfaceRS 232 Transfer characteristics Input I and II Measurement range0.001 ... 1000 Hz Resolutionslip monitoring: 1% frequency measurement: 0,1% of measured value; but >0.001Hz Accuracyslip monitoring: 1% frequency measurement: 0.5% of measured value; but >0.001Hz Measuring timefrequency measurement: < 100 ms Influence of ambient temperature0.003 %/K (30 ppm) Output I, II Response delay≤ 200 ms Output V Resolution< 10 µA Accuracy< 30 µA Influence of ambient temperature0.005 %/K (50 ppm) Galvanic isolation Input I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Input III, IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Mutual output I, II, IIIreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Mutual output I, II, IV reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III, IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III, IV/input III, IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Output III, IV/Vbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Output V/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/output III, IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Indicators/settings Display elementsLEDs , display Control elementsControl panel Configurationvia operating buttons via PACTware Labelingspace for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61326-1:2006 Low voltage Directive 2014/35/EUEN 61010-1:2010 Conformity Electromagnetic compatibilityNE 21:2006 Degree of protectionIEC 60529:2001 InputEN 60947-5-6:2000 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Mechanical specifications Degree of protectionIP20 Connectionscrew terminals Mass300 g Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C2 Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001 General information Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. Classifications SystemClasscode ECLASS 11.027210128 ECLASS 10.0.127210128 ECLASS 9.027210128 ECLASS 8.027210190 ECLASS 5.127210121 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007